1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 +/t
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -18,4 +18,99 @@
18 18  |Cooling|Low-noise forced air
19 19  |Sound level|< 70 dB
20 20  
21 - /h1
23 +
24 +
25 += Principal Dimensions =
26 +
27 +[[**Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.**>>image:1788844179033-844.png]]
28 +
29 +
30 += Laser-Source Variants =
31 +
32 +The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
33 +
34 +(% class="table-condensed table-striped" %)
35 +|**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
36 +|F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
37 +|F30|Pulsed fiber|30 W|1 mJ|M2 < 1.5
38 +|F50|Pulsed fiber|50 W|1 mJ|M2 < 1.8
39 +|M20|Pulsed MOPA fiber|20 W|0.7 mJ|M2 < 1.3
40 +|M30|Pulsed MOPA fiber|30 W|1 mJ|M2 < 1.3
41 +
42 +
43 +
44 += Pulse and Electrical Data =
45 +
46 +(% class="table-condensed table-striped" %)
47 +|**Model**|**Wavelength**|**Pulse frequency**|**Pulse duration**|**Power consumption**
48 +|F20|1060-1070 nm|20-60 kHz|100 ns|< 200 W
49 +|F30|1060-1070 nm|30-60 kHz|100 ns|< 300 W
50 +|F50|1060-1070 nm|50-100 kHz|100 ns|< 340 W
51 +|M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
52 +|M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
53 +
54 +(% class="box infomessage" %)
55 +(((
56 + **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
57 +)))
58 +
59 +
60 +
61 += Common Optical and Mechanical Data =
62 +
63 +(% class="table-condensed table-striped" %)
64 +|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
65 +|Fibre length|m|3
66 +|Standard lens|-|F-Theta, 160 mm focal length
67 +|Standard working distance|mm|176
68 +|Standard field size|mm|110 x 110
69 +|Lens wavelength|nm|1064
70 +|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
71 +|Laser-head dimensions|mm|367 x 131 x 131
72 +
73 +(% class="box warningmessage" %)
74 +(((
75 + **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
76 +)))
77 +
78 +
79 +
80 += Operating and Installation Conditions =
81 +
82 +(% class="table-condensed table-striped" %)
83 +|**Condition**|**Requirement**
84 +|Ambient temperature|+15 degrees C to +35 degrees C
85 +|Relative humidity|No higher than 90%, non-condensing
86 +|After a major temperature change|Allow the system to return to room temperature before commissioning
87 +|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
88 +|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
89 +|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
90 +
91 +
92 +
93 += Interfaces and Supply - Overview =
94 +
95 +(% class="table-condensed table-striped" %)
96 +|**Connection**|**Manual description**|**Purpose**
97 +|X0|230 V / 600 W, including main switch|Mains-supply interface
98 +|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
99 +|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
100 +|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
101 +|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
102 +
103 +(% class="box errormessage" %)
104 +(((
105 + **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
106 +)))
107 +
108 +
109 +
110 += Verification Before Use =
111 +
112 +* Match the model designation and serial number to the nameplate and order documentation.
113 +* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
114 +* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
115 +* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
116 +* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.
117 +
118 +