Description: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
Configuration control: The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
System Identification
Property
Manual specification
System type
Integration laser
Laser classification
Laser Class 4
Protection rating
IP21
Available variants
F20, F30, F50, M20, and M30
Cooling
Low-noise forced air
Sound level
< 70 dB
Principal Dimensions
Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.
Laser-Source Variants
The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
Model
Laser source
Nominal power
Pulse energy
Beam quality
F20
Pulsed fiber
20 W
1 mJ
M2 < 1.5
F30
Pulsed fiber
30 W
1 mJ
M2 < 1.5
F50
Pulsed fiber
50 W
1 mJ
M2 < 1.8
M20
Pulsed MOPA fiber
20 W
0.7 mJ
M2 < 1.3
M30
Pulsed MOPA fiber
30 W
1 mJ
M2 < 1.3
Pulse and Electrical Data
Model
Wavelength
Pulse frequency
Pulse duration
Power consumption
F20
1060-1070 nm
20-60 kHz
100 ns
< 200 W
F30
1060-1070 nm
30-60 kHz
100 ns
< 300 W
F50
1060-1070 nm
50-100 kHz
100 ns
< 340 W
M20
1060-1070 nm
2-550 kHz
2-550 ns
< 150 W
M30
1060-1070 nm
2-550 kHz
2-550 ns
< 170 W
Do not substitute process settings: These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
Common Optical and Mechanical Data
Property
Unit
F20 / F30 / F50 / M20 / M30
Fibre length
m
3
Standard lens
-
F-Theta, 160 mm focal length
Standard working distance
mm
176
Standard field size
mm
110 x 110
Lens wavelength
nm
1064
Laser-rack dimensions (L x W x H)
mm
550 x 441 x 162
Laser-head dimensions
mm
367 x 131 x 131
Standard optics: The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
Operating and Installation Conditions
Condition
Requirement
Ambient temperature
+15 degrees C to +35 degrees C
Relative humidity
No higher than 90%, non-condensing
After a major temperature change
Allow the system to return to room temperature before commissioning
Cooling-air openings
Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
Operating environment
Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
Process emissions
Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
Interfaces and Supply - Overview
Connection
Manual description
Purpose
X0
230 V / 600 W, including main switch
Mains-supply interface
X1
25-pin Sub-D socket
Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
X1 outputs
24 V when active; Imax 250 mA
External status and assigned production outputs referenced to X1.25 GND
X2
25-pin Sub-D plug
Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
Rack data connections
USB, Ethernet, and HDMI
Workstation, network, and display connections according to the delivered integration