Änderungen von Dokument Auto-Light Interfaces and Connection Examples
Zuletzt geändert von jadomatis am 2026/09/08 08:58
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
-
Anhänge (0 geändert, 0 hinzugefügt, 2 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -7,10 +7,20 @@ 7 7 8 8 ---- 9 9 10 - 11 11 = Connection Locations = 12 12 13 13 X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement. 14 14 14 +[[image:1788847354911-289.png]] 15 + 15 15 17 += X0 Mains Supply = 18 + 19 +The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation. 20 + 21 +(% class="box warningmessage" %) 22 +((( 23 +**Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements. 24 +))) 25 + 16 16
- 1788848413336-918.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Größe
-
... ... @@ -1,1 +1,0 @@ 1 -14.1 KB - Inhalt
- 1788848609160-695.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Größe
-
... ... @@ -1,1 +1,0 @@ 1 -278.1 KB - Inhalt