Last modified by jadomatis on 2026/09/08 08:58

From version 21.1
edited by jadomatis
on 2026/09/08 08:58
Change comment: There is no comment for this version
To version 20.8
edited by jadomatis
on 2026/09/08 08:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
2 2  
3 -{{toc/}}
4 -
5 5  (% class="box errormessage" %)
6 6  (((
7 7  **Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.
... ... @@ -9,6 +9,7 @@
9 9  
10 10  ----
11 11  
10 +
12 12  = Connection Locations =
13 13  
14 14  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
... ... @@ -135,36 +135,4 @@
135 135  |(% style="width:108px" %)24|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
136 136  |(% style="width:108px" %)25|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
137 137  
138 -
139 -
140 -= X2 Functional Grouping =
141 -
142 -(% class="table-condensed table-striped" style="width:1125px" %)
143 -|**Axis / function**|(% style="width:391px" %)**Pin(s)**|(% style="width:481px" %)**Direction stated in manual**
144 -|X axis|(% style="width:391px" %)1 Direction; 2 Step; 9 Zero|(% style="width:481px" %)Outputs on all three pins, as stated
145 -|Y axis|(% style="width:391px" %)3 Direction; 4 Step; 11 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
146 -|Z axis|(% style="width:391px" %)5 Direction; 6 Step; 13 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
147 -|R axis|(% style="width:391px" %)7 Direction; 8 Step; 15 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
148 -|Reference|(% style="width:391px" %)17 GND; 19 +5 V|(% style="width:481px" %)Outputs, as stated
149 -|Not connected|(% style="width:391px" %)10, 12, 14, 16, 18, 20-25|(% style="width:481px" %)NC
150 -
151 -
152 -
153 -= Integration and Commissioning Checks =
154 -
155 -* (((
156 -Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors.
157 -)))
158 -* Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation.
159 -* Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation.
160 -* Validate both emergency-stop channels, both shutter channels, acknowledgement behavior, guard opening, status outputs, and prevention of unexpected restart before laser operation is released.
161 -* Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission.
162 -* For every installed axis, verify direction, step scaling, travel limits, zero/reference behavior, and safe motion before placing a workpiece in the marking area.
163 -* Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack.
164 -
165 -(% class="box infomessage" %)
166 -(((
167 - **Troubleshooting boundary: **Operators may record external status and host messages. Pin-level measurement, connector removal, rewiring, safety-module work, and axis electrical testing require isolation and personnel authorized for the delivered integration. Use the Auto-Light Troubleshooting article for symptom-based diagnosis.
168 -)))
169 -