Last modified by jadomatis on 2026/09/08 08:58

From version 21.1
edited by jadomatis
on 2026/09/08 08:58
Change comment: There is no comment for this version
To version 20.7
edited by jadomatis
on 2026/09/08 08:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
2 2  
3 -{{toc/}}
4 -
5 5  (% class="box errormessage" %)
6 6  (((
7 7  **Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.
... ... @@ -9,6 +9,7 @@
9 9  
10 10  ----
11 11  
10 +
12 12  = Connection Locations =
13 13  
14 14  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
... ... @@ -102,69 +102,4 @@
102 102  **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.
103 103  )))
104 104  
105 -
106 -= X2 Axes Interface - 25-pin Sub-D Plug =
107 -
108 -X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation.
109 -
110 -(% class="table-condensed table-striped" style="width:492px" %)
111 -|=(% style="width: 108px;" %)Pin|=(% style="width: 174px;" %)Direction|=(% style="width: 207px;" %)Description
112 -|(% style="width:108px" %)1|(% style="width:174px" %)Output|(% style="width:207px" %)Direction X
113 -|(% style="width:108px" %)2|(% style="width:174px" %)Output|(% style="width:207px" %)Step X
114 -|(% style="width:108px" %)3|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Y
115 -|(% style="width:108px" %)4|(% style="width:174px" %)Output|(% style="width:207px" %)Step Y
116 -|(% style="width:108px" %)5|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Z
117 -|(% style="width:108px" %)6|(% style="width:174px" %)Output|(% style="width:207px" %)Step Z
118 -|(% style="width:108px" %)7|(% style="width:174px" %)Output|(% style="width:207px" %)Direction R
119 -|(% style="width:108px" %)8|(% style="width:174px" %)Output|(% style="width:207px" %)Step R
120 -|(% style="width:108px" %)9|(% style="width:174px" %)Output|(% style="width:207px" %)Zero X
121 -|(% style="width:108px" %)10|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
122 -|(% style="width:108px" %)11|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Y
123 -|(% style="width:108px" %)12|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
124 -|(% style="width:108px" %)13|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Z
125 -|(% style="width:108px" %)14|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
126 -|(% style="width:108px" %)15|(% style="width:174px" %)Input|(% style="width:207px" %)Zero R
127 -|(% style="width:108px" %)16|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
128 -|(% style="width:108px" %)17|(% style="width:174px" %)Output|(% style="width:207px" %)GND
129 -|(% style="width:108px" %)18|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
130 -|(% style="width:108px" %)19|(% style="width:174px" %)Output|(% style="width:207px" %)+5V supply
131 -|(% style="width:108px" %)20|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
132 -|(% style="width:108px" %)21|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
133 -|(% style="width:108px" %)22|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
134 -|(% style="width:108px" %)23|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
135 -|(% style="width:108px" %)24|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
136 -|(% style="width:108px" %)25|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
137 -
138 -
139 -
140 -= X2 Functional Grouping =
141 -
142 -(% class="table-condensed table-striped" style="width:1125px" %)
143 -|**Axis / function**|(% style="width:391px" %)**Pin(s)**|(% style="width:481px" %)**Direction stated in manual**
144 -|X axis|(% style="width:391px" %)1 Direction; 2 Step; 9 Zero|(% style="width:481px" %)Outputs on all three pins, as stated
145 -|Y axis|(% style="width:391px" %)3 Direction; 4 Step; 11 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
146 -|Z axis|(% style="width:391px" %)5 Direction; 6 Step; 13 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
147 -|R axis|(% style="width:391px" %)7 Direction; 8 Step; 15 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
148 -|Reference|(% style="width:391px" %)17 GND; 19 +5 V|(% style="width:481px" %)Outputs, as stated
149 -|Not connected|(% style="width:391px" %)10, 12, 14, 16, 18, 20-25|(% style="width:481px" %)NC
150 -
151 -
152 -
153 -= Integration and Commissioning Checks =
154 -
155 -* (((
156 -Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors.
157 -)))
158 -* Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation.
159 -* Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation.
160 -* Validate both emergency-stop channels, both shutter channels, acknowledgement behavior, guard opening, status outputs, and prevention of unexpected restart before laser operation is released.
161 -* Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission.
162 -* For every installed axis, verify direction, step scaling, travel limits, zero/reference behavior, and safe motion before placing a workpiece in the marking area.
163 -* Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack.
164 -
165 -(% class="box infomessage" %)
166 -(((
167 - **Troubleshooting boundary: **Operators may record external status and host messages. Pin-level measurement, connector removal, rewiring, safety-module work, and axis electrical testing require isolation and personnel authorized for the delivered integration. Use the Auto-Light Troubleshooting article for symptom-based diagnosis.
168 -)))