Last modified by jadomatis on 2026/09/08 08:58

From version 20.6
edited by jadomatis
on 2026/09/08 08:39
Change comment: There is no comment for this version
To version 21.1
edited by jadomatis
on 2026/09/08 08:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 1  **Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box errormessage" %)
4 4  (((
5 5  **Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.
... ... @@ -7,7 +7,6 @@
7 7  
8 8  ----
9 9  
10 -
11 11  = Connection Locations =
12 12  
13 13  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
... ... @@ -96,8 +96,74 @@
96 96  
97 97  [[**External-output example. Confirm the selected output and load connection against the delivered electrical drawing.**>>image:1788848686112-729.png]]
98 98  
99 -
100 100  (% class="box warningmessage" %)
101 101  (((
102 102  **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.
103 103  )))
104 +
105 +
106 += X2 Axes Interface - 25-pin Sub-D Plug =
107 +
108 +X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation.
109 +
110 +(% class="table-condensed table-striped" style="width:492px" %)
111 +|=(% style="width: 108px;" %)Pin|=(% style="width: 174px;" %)Direction|=(% style="width: 207px;" %)Description
112 +|(% style="width:108px" %)1|(% style="width:174px" %)Output|(% style="width:207px" %)Direction X
113 +|(% style="width:108px" %)2|(% style="width:174px" %)Output|(% style="width:207px" %)Step X
114 +|(% style="width:108px" %)3|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Y
115 +|(% style="width:108px" %)4|(% style="width:174px" %)Output|(% style="width:207px" %)Step Y
116 +|(% style="width:108px" %)5|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Z
117 +|(% style="width:108px" %)6|(% style="width:174px" %)Output|(% style="width:207px" %)Step Z
118 +|(% style="width:108px" %)7|(% style="width:174px" %)Output|(% style="width:207px" %)Direction R
119 +|(% style="width:108px" %)8|(% style="width:174px" %)Output|(% style="width:207px" %)Step R
120 +|(% style="width:108px" %)9|(% style="width:174px" %)Output|(% style="width:207px" %)Zero X
121 +|(% style="width:108px" %)10|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
122 +|(% style="width:108px" %)11|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Y
123 +|(% style="width:108px" %)12|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
124 +|(% style="width:108px" %)13|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Z
125 +|(% style="width:108px" %)14|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
126 +|(% style="width:108px" %)15|(% style="width:174px" %)Input|(% style="width:207px" %)Zero R
127 +|(% style="width:108px" %)16|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
128 +|(% style="width:108px" %)17|(% style="width:174px" %)Output|(% style="width:207px" %)GND
129 +|(% style="width:108px" %)18|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
130 +|(% style="width:108px" %)19|(% style="width:174px" %)Output|(% style="width:207px" %)+5V supply
131 +|(% style="width:108px" %)20|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
132 +|(% style="width:108px" %)21|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
133 +|(% style="width:108px" %)22|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
134 +|(% style="width:108px" %)23|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
135 +|(% style="width:108px" %)24|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
136 +|(% style="width:108px" %)25|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
137 +
138 +
139 +
140 += X2 Functional Grouping =
141 +
142 +(% class="table-condensed table-striped" style="width:1125px" %)
143 +|**Axis / function**|(% style="width:391px" %)**Pin(s)**|(% style="width:481px" %)**Direction stated in manual**
144 +|X axis|(% style="width:391px" %)1 Direction; 2 Step; 9 Zero|(% style="width:481px" %)Outputs on all three pins, as stated
145 +|Y axis|(% style="width:391px" %)3 Direction; 4 Step; 11 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
146 +|Z axis|(% style="width:391px" %)5 Direction; 6 Step; 13 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
147 +|R axis|(% style="width:391px" %)7 Direction; 8 Step; 15 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input
148 +|Reference|(% style="width:391px" %)17 GND; 19 +5 V|(% style="width:481px" %)Outputs, as stated
149 +|Not connected|(% style="width:391px" %)10, 12, 14, 16, 18, 20-25|(% style="width:481px" %)NC
150 +
151 +
152 +
153 += Integration and Commissioning Checks =
154 +
155 +* (((
156 +Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors.
157 +)))
158 +* Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation.
159 +* Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation.
160 +* Validate both emergency-stop channels, both shutter channels, acknowledgement behavior, guard opening, status outputs, and prevention of unexpected restart before laser operation is released.
161 +* Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission.
162 +* For every installed axis, verify direction, step scaling, travel limits, zero/reference behavior, and safe motion before placing a workpiece in the marking area.
163 +* Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack.
164 +
165 +(% class="box infomessage" %)
166 +(((
167 + **Troubleshooting boundary: **Operators may record external status and host messages. Pin-level measurement, connector removal, rewiring, safety-module work, and axis electrical testing require isolation and personnel authorized for the delivered integration. Use the Auto-Light Troubleshooting article for symptom-based diagnosis.
168 +)))
169 +
170 +