Changes for page Auto-Light Interfaces and Connection Examples
Last modified by jadomatis on 2026/09/08 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,8 +96,74 @@ 96 96 97 97 [[**External-output example. Confirm the selected output and load connection against the delivered electrical drawing.**>>image:1788848686112-729.png]] 98 98 99 - 100 100 (% class="box warningmessage" %) 101 101 ((( 102 102 **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection. 103 103 ))) 103 + 104 + 105 += X2 Axes Interface - 25-pin Sub-D Plug = 106 + 107 +X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation. 108 + 109 +(% class="table-condensed table-striped" style="width:492px" %) 110 +|=(% style="width: 108px;" %)Pin|=(% style="width: 174px;" %)Direction|=(% style="width: 207px;" %)Description 111 +|(% style="width:108px" %)1|(% style="width:174px" %)Output|(% style="width:207px" %)Direction X 112 +|(% style="width:108px" %)2|(% style="width:174px" %)Output|(% style="width:207px" %)Step X 113 +|(% style="width:108px" %)3|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Y 114 +|(% style="width:108px" %)4|(% style="width:174px" %)Output|(% style="width:207px" %)Step Y 115 +|(% style="width:108px" %)5|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Z 116 +|(% style="width:108px" %)6|(% style="width:174px" %)Output|(% style="width:207px" %)Step Z 117 +|(% style="width:108px" %)7|(% style="width:174px" %)Output|(% style="width:207px" %)Direction R 118 +|(% style="width:108px" %)8|(% style="width:174px" %)Output|(% style="width:207px" %)Step R 119 +|(% style="width:108px" %)9|(% style="width:174px" %)Output|(% style="width:207px" %)Zero X 120 +|(% style="width:108px" %)10|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 121 +|(% style="width:108px" %)11|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Y 122 +|(% style="width:108px" %)12|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 123 +|(% style="width:108px" %)13|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Z 124 +|(% style="width:108px" %)14|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 125 +|(% style="width:108px" %)15|(% style="width:174px" %)Input|(% style="width:207px" %)Zero R 126 +|(% style="width:108px" %)16|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 127 +|(% style="width:108px" %)17|(% style="width:174px" %)Output|(% style="width:207px" %)GND 128 +|(% style="width:108px" %)18|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 129 +|(% style="width:108px" %)19|(% style="width:174px" %)Output|(% style="width:207px" %)+5V supply 130 +|(% style="width:108px" %)20|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 131 +|(% style="width:108px" %)21|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 132 +|(% style="width:108px" %)22|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 133 +|(% style="width:108px" %)23|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 134 +|(% style="width:108px" %)24|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 135 +|(% style="width:108px" %)25|(% style="width:174px" %)-|(% style="width:207px" %)Not connected 136 + 137 + 138 + 139 += X2 Functional Grouping = 140 + 141 +(% class="table-condensed table-striped" style="width:1125px" %) 142 +|**Axis / function**|(% style="width:391px" %)**Pin(s)**|(% style="width:481px" %)**Direction stated in manual** 143 +|X axis|(% style="width:391px" %)1 Direction; 2 Step; 9 Zero|(% style="width:481px" %)Outputs on all three pins, as stated 144 +|Y axis|(% style="width:391px" %)3 Direction; 4 Step; 11 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input 145 +|Z axis|(% style="width:391px" %)5 Direction; 6 Step; 13 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input 146 +|R axis|(% style="width:391px" %)7 Direction; 8 Step; 15 Zero|(% style="width:481px" %)Direction/Step outputs; Zero input 147 +|Reference|(% style="width:391px" %)17 GND; 19 +5 V|(% style="width:481px" %)Outputs, as stated 148 +|Not connected|(% style="width:391px" %)10, 12, 14, 16, 18, 20-25|(% style="width:481px" %)NC 149 + 150 + 151 + 152 += Integration and Commissioning Checks = 153 + 154 +* ((( 155 +Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors. 156 +))) 157 +* Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation. 158 +* Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation. 159 +* Validate both emergency-stop channels, both shutter channels, acknowledgement behavior, guard opening, status outputs, and prevention of unexpected restart before laser operation is released. 160 +* Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission. 161 +* For every installed axis, verify direction, step scaling, travel limits, zero/reference behavior, and safe motion before placing a workpiece in the marking area. 162 +* Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack. 163 + 164 +(% class="box infomessage" %) 165 +((( 166 + **Troubleshooting boundary: **Operators may record external status and host messages. Pin-level measurement, connector removal, rewiring, safety-module work, and axis electrical testing require isolation and personnel authorized for the delivered integration. Use the Auto-Light Troubleshooting article for symptom-based diagnosis. 167 +))) 168 + 169 +