Last modified by jadomatis on 2026/09/08 08:58

From version 20.5
edited by jadomatis
on 2026/09/08 08:37
Change comment: There is no comment for this version
To version 20.6
edited by jadomatis
on 2026/09/08 08:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -60,8 +60,10 @@
60 60  
61 61  [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788848686109-592.png]]
62 62  
63 -
63 +(% class="box warningmessage" %)
64 +(((
64 64  **Reset is not a safety function: **Acknowledgement may be accepted only after the cause of the stop has been removed, the hazard area is clear, and the host safety system permits reset. It must not initiate hazardous movement or laser emission by itself.
66 +)))
65 65  
66 66  
67 67  = X1 Shutter Connection Examples =
... ... @@ -75,8 +75,10 @@
75 75  
76 76  [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788848686110-868.png]]
77 77  
78 -
80 +(% class="box errormessage" %)
81 +(((
79 79  **Integration requirement: **The protective enclosure, access monitoring, shutter channels, acknowledgement logic, emergency stop, and emission warning must operate as one validated safety concept. Never use the X1 examples as a stand-alone circuit design.
83 +)))
80 80  
81 81  
82 82  = X1 External Inputs =
... ... @@ -93,4 +93,7 @@
93 93  [[**External-output example. Confirm the selected output and load connection against the delivered electrical drawing.**>>image:1788848686112-729.png]]
94 94  
95 95  
100 +(% class="box warningmessage" %)
101 +(((
96 96  **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.
103 +)))