Changes for page Auto-Light Interfaces and Connection Examples
Last modified by jadomatis on 2026/09/08 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -50,13 +50,13 @@ 50 50 51 51 Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine. 52 52 53 -[[ Caption>>image:1788848686108-737.png]]53 +[[image:1788848686108-737.png]] 54 54 55 55 Example: dual emergency-stop circuits at X1.1-X1.4. 56 56 57 57 Emergency-stop acknowledgement is provided at X1.5/X1.6. The source manual states that acknowledgement is required at every restart of the system and after every operation of the emergency stop. 58 58 59 -[[ Caption>>image:1788848686109-592.png]]59 +[[image:1788848686109-592.png]] 60 60 61 61 Example: emergency-stop acknowledgement at X1.5/X1.6. 62 62 ... ... @@ -69,13 +69,13 @@ 69 69 70 70 The shutter interface also uses two external channels. Circuit 1 uses X1.7/X1.8 and circuit 2 uses X1.9/X1.10. The manual requires the shutter circuit to be interrupted whenever the protective enclosure is opened. 71 71 72 -[[ Caption>>image:1788848686109-891.png]]72 +[[image:1788848686109-891.png]] 73 73 74 74 Example: dual shutter circuits at X1.7-X1.10. 75 75 76 76 Shutter acknowledgement is provided at X1.11/X1.12. A closed and validated shutter circuit enables the laser system's active mode. The source states that laser-energy emission is possible only in active mode; a closed circuit is permission, not a marking command. 77 77 78 -[[ Caption>>image:1788848686110-868.png]]78 +[[image:1788848686110-868.png]] 79 79 80 80 Example: shutter acknowledgement at X1.11/X1.12. 81 81 ... ... @@ -86,11 +86,10 @@ 86 86 87 87 The manual states that the X1 inputs are switched using the internal 24 V auxiliary supply at X1.13. Its example closes an external contact between X1.13 and X1.14 to issue External START. X1.15 is External STOP; X1.21 and X1.22 are Inputs 4 and 5. 88 88 89 -[[ Caption>>image:1788848686111-492.png]]89 +[[image:1788848686111-492.png]] 90 90 91 - Example: external input switched from X1.13 to X1.14.91 +//Figure 6 - Manual example: external input switched from X1.13 to X1.14.// 92 92 93 - 94 94 = X1 External Outputs = 95 95 96 96 The source states that an active output supplies 24 V and is used with output ground at X1.25. The maximum output current is 250 mA. Status outputs are X1.16-X1.20; assignable Outputs 4 and 5 are X1.23/X1.24. ... ... @@ -97,6 +97,6 @@ 97 97 98 98 [[image:1788848686112-729.png]] 99 99 100 - External-output example. Confirm the selected output and load connection against the delivered electrical drawing.99 +//Figure 7 - Manual external-output example. Confirm the selected output and load connection against the delivered electrical drawing.// 101 101 102 102 **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.