... ... @@ -50,13 +50,13 @@
50 50  
51 51  Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.
52 52  
53 -[[image:1788848686108-737.png]]
53 +[[Caption>>image:1788848686108-737.png]]
54 54  
55 55  Example: dual emergency-stop circuits at X1.1-X1.4.
56 56  
57 57  Emergency-stop acknowledgement is provided at X1.5/X1.6. The source manual states that acknowledgement is required at every restart of the system and after every operation of the emergency stop.
58 58  
59 -[[image:1788848686109-592.png]]
59 +[[Caption>>image:1788848686109-592.png]]
60 60  
61 61  Example: emergency-stop acknowledgement at X1.5/X1.6.
62 62  
... ... @@ -69,13 +69,13 @@
69 69  
70 70  The shutter interface also uses two external channels. Circuit 1 uses X1.7/X1.8 and circuit 2 uses X1.9/X1.10. The manual requires the shutter circuit to be interrupted whenever the protective enclosure is opened.
71 71  
72 -[[image:1788848686109-891.png]]
72 +[[Caption>>image:1788848686109-891.png]]
73 73  
74 74  Example: dual shutter circuits at X1.7-X1.10.
75 75  
76 76  Shutter acknowledgement is provided at X1.11/X1.12. A closed and validated shutter circuit enables the laser system's active mode. The source states that laser-energy emission is possible only in active mode; a closed circuit is permission, not a marking command.
77 77  
78 -[[image:1788848686110-868.png]]
78 +[[Caption>>image:1788848686110-868.png]]
79 79  
80 80  Example: shutter acknowledgement at X1.11/X1.12.
81 81  
... ... @@ -86,10 +86,11 @@
86 86  
87 87  The manual states that the X1 inputs are switched using the internal 24 V auxiliary supply at X1.13. Its example closes an external contact between X1.13 and X1.14 to issue External START. X1.15 is External STOP; X1.21 and X1.22 are Inputs 4 and 5.
88 88  
89 -[[image:1788848686111-492.png]]
89 +[[Caption>>image:1788848686111-492.png]]
90 90  
91 -//Figure 6 - Manual example: external input switched from X1.13 to X1.14.//
91 +Example: external input switched from X1.13 to X1.14.
92 92  
93 +
93 93  = X1 External Outputs =
94 94  
95 95  The source states that an active output supplies 24 V and is used with output ground at X1.25. The maximum output current is 250 mA. Status outputs are X1.16-X1.20; assignable Outputs 4 and 5 are X1.23/X1.24.
... ... @@ -96,6 +96,6 @@
96 96  
97 97  [[image:1788848686112-729.png]]
98 98  
99 -//Figure 7 - Manual external-output example. Confirm the selected output and load connection against the delivered electrical drawing.//
100 +External-output example. Confirm the selected output and load connection against the delivered electrical drawing.
100 100  
101 101  **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.