Last modified by jadomatis on 2026/09/08 08:58

From version 20.2
edited by jadomatis
on 2026/09/08 08:34
Change comment: There is no comment for this version
To version 19.2
edited by jadomatis
on 2026/09/08 08:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,19 +12,21 @@
12 12  
13 13  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
14 14  
15 -[[**Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.**>>image:1788848686104-199.png]]
15 +[[image:1788848686104-199.png]]
16 16  
17 +//Figure 1 - Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.//
17 17  
19 +
20 +
21 +
18 18  = X0 Mains Supply =
19 19  
20 -X0 is a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
24 +The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
21 21  
22 22  **Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
23 23  
24 -
25 25  = X1 Laser Interface - Pin Assignment =
26 26  
27 -(% class="table-condensed table-striped" %)
28 28  |**Pin(s)**|**Signal**|**Manual description / use**
29 29  |1-2|Emergency-stop circuit 1|External wiring through a safety module required
30 30  |3-4|Emergency-stop circuit 2|External wiring through a safety module required