Last modified by jadomatis on 2026/09/08 08:58

From version 20.1
edited by jadomatis
on 2026/09/08 08:32
Change comment: There is no comment for this version
To version 20.8
edited by jadomatis
on 2026/09/08 08:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,21 +12,22 @@
12 12  
13 13  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
14 14  
15 -[[image:1788848686104-199.png]]
15 +[[**Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.**>>image:1788848686104-199.png]]
16 16  
17 -//Figure 1 - Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.//
18 18  
19 -
20 -
21 -
22 22  = X0 Mains Supply =
23 23  
24 -The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
20 +X0 is a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
25 25  
22 +(% class="box warningmessage" %)
23 +(((
26 26  **Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
25 +)))
27 27  
27 +
28 28  = X1 Laser Interface - Pin Assignment =
29 29  
30 +(% class="table-condensed table-striped" %)
30 30  |**Pin(s)**|**Signal**|**Manual description / use**
31 31  |1-2|Emergency-stop circuit 1|External wiring through a safety module required
32 32  |3-4|Emergency-stop circuit 2|External wiring through a safety module required
... ... @@ -48,60 +48,89 @@
48 48  
49 49  
50 50  
51 -
52 -
53 53  = X1 Emergency-Stop Connection Examples =
54 54  
55 -The manual example routes two external emergency-stop channels through a safety module. Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.
54 +Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.
56 56  
57 -[[image:1788848686108-737.png]]
56 +[[**Example: dual emergency-stop circuits at X1.1-X1.4.**>>image:1788848686108-737.png]]
58 58  
59 -//Figure 2 - Manual example: dual emergency-stop circuits at X1.1-X1.4.//
60 60  
61 61  Emergency-stop acknowledgement is provided at X1.5/X1.6. The source manual states that acknowledgement is required at every restart of the system and after every operation of the emergency stop.
62 62  
63 -[[image:1788848686109-592.png]]
61 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788848686109-592.png]]
64 64  
65 -//Figure 3 - Manual example: emergency-stop acknowledgement at X1.5/X1.6.//
66 -
63 +(% class="box warningmessage" %)
64 +(((
67 67  **Reset is not a safety function: **Acknowledgement may be accepted only after the cause of the stop has been removed, the hazard area is clear, and the host safety system permits reset. It must not initiate hazardous movement or laser emission by itself.
66 +)))
68 68  
69 69  
70 -
71 -
72 72  = X1 Shutter Connection Examples =
73 73  
74 74  The shutter interface also uses two external channels. Circuit 1 uses X1.7/X1.8 and circuit 2 uses X1.9/X1.10. The manual requires the shutter circuit to be interrupted whenever the protective enclosure is opened.
75 75  
76 -[[image:1788848686109-891.png]]
73 +[[**Example: dual shutter circuits at X1.7-X1.10.**>>image:1788848686109-891.png]]
77 77  
78 -//Figure 4 - Manual example: dual shutter circuits at X1.7-X1.10.//
79 79  
80 80  Shutter acknowledgement is provided at X1.11/X1.12. A closed and validated shutter circuit enables the laser system's active mode. The source states that laser-energy emission is possible only in active mode; a closed circuit is permission, not a marking command.
81 81  
82 -[[image:1788848686110-868.png]]
78 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788848686110-868.png]]
83 83  
84 -//Figure 5 - Manual example: shutter acknowledgement at X1.11/X1.12.//
85 -
80 +(% class="box errormessage" %)
81 +(((
86 86  **Integration requirement: **The protective enclosure, access monitoring, shutter channels, acknowledgement logic, emergency stop, and emission warning must operate as one validated safety concept. Never use the X1 examples as a stand-alone circuit design.
83 +)))
87 87  
88 88  
89 -
90 -
91 91  = X1 External Inputs =
92 92  
93 93  The manual states that the X1 inputs are switched using the internal 24 V auxiliary supply at X1.13. Its example closes an external contact between X1.13 and X1.14 to issue External START. X1.15 is External STOP; X1.21 and X1.22 are Inputs 4 and 5.
94 94  
95 -[[image:1788848686111-492.png]]
90 +[[**Example: external input switched from X1.13 to X1.14.**>>image:1788848686111-492.png]]
96 96  
97 -//Figure 6 - Manual example: external input switched from X1.13 to X1.14.//
98 98  
99 99  = X1 External Outputs =
100 100  
101 101  The source states that an active output supplies 24 V and is used with output ground at X1.25. The maximum output current is 250 mA. Status outputs are X1.16-X1.20; assignable Outputs 4 and 5 are X1.23/X1.24.
102 102  
103 -[[image:1788848686112-729.png]]
97 +[[**External-output example. Confirm the selected output and load connection against the delivered electrical drawing.**>>image:1788848686112-729.png]]
104 104  
105 -//Figure 7 - Manual external-output example. Confirm the selected output and load connection against the delivered electrical drawing.//
106 -
99 +(% class="box warningmessage" %)
100 +(((
107 107  **Diagram limitation: **The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.
102 +)))
103 +
104 +
105 += X2 Axes Interface - 25-pin Sub-D Plug =
106 +
107 +X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation.
108 +
109 +(% class="table-condensed table-striped" style="width:492px" %)
110 +|=(% style="width: 108px;" %)Pin|=(% style="width: 174px;" %)Direction|=(% style="width: 207px;" %)Description
111 +|(% style="width:108px" %)1|(% style="width:174px" %)Output|(% style="width:207px" %)Direction X
112 +|(% style="width:108px" %)2|(% style="width:174px" %)Output|(% style="width:207px" %)Step X
113 +|(% style="width:108px" %)3|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Y
114 +|(% style="width:108px" %)4|(% style="width:174px" %)Output|(% style="width:207px" %)Step Y
115 +|(% style="width:108px" %)5|(% style="width:174px" %)Output|(% style="width:207px" %)Direction Z
116 +|(% style="width:108px" %)6|(% style="width:174px" %)Output|(% style="width:207px" %)Step Z
117 +|(% style="width:108px" %)7|(% style="width:174px" %)Output|(% style="width:207px" %)Direction R
118 +|(% style="width:108px" %)8|(% style="width:174px" %)Output|(% style="width:207px" %)Step R
119 +|(% style="width:108px" %)9|(% style="width:174px" %)Output|(% style="width:207px" %)Zero X
120 +|(% style="width:108px" %)10|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
121 +|(% style="width:108px" %)11|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Y
122 +|(% style="width:108px" %)12|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
123 +|(% style="width:108px" %)13|(% style="width:174px" %)Input|(% style="width:207px" %)Zero Z
124 +|(% style="width:108px" %)14|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
125 +|(% style="width:108px" %)15|(% style="width:174px" %)Input|(% style="width:207px" %)Zero R
126 +|(% style="width:108px" %)16|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
127 +|(% style="width:108px" %)17|(% style="width:174px" %)Output|(% style="width:207px" %)GND
128 +|(% style="width:108px" %)18|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
129 +|(% style="width:108px" %)19|(% style="width:174px" %)Output|(% style="width:207px" %)+5V supply
130 +|(% style="width:108px" %)20|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
131 +|(% style="width:108px" %)21|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
132 +|(% style="width:108px" %)22|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
133 +|(% style="width:108px" %)23|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
134 +|(% style="width:108px" %)24|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
135 +|(% style="width:108px" %)25|(% style="width:174px" %)-|(% style="width:207px" %)Not connected
136 +
137 +