Last modified by jadomatis on 2026/09/08 08:58

From version 20.1
edited by jadomatis
on 2026/09/08 08:32
Change comment: There is no comment for this version
To version 20.2
edited by jadomatis
on 2026/09/08 08:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,21 +12,19 @@
12 12  
13 13  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
14 14  
15 -[[image:1788848686104-199.png]]
15 +[[**Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.**>>image:1788848686104-199.png]]
16 16  
17 -//Figure 1 - Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.//
18 18  
19 -
20 -
21 -
22 22  = X0 Mains Supply =
23 23  
24 -The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
20 +X0 is a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
25 25  
26 26  **Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
27 27  
24 +
28 28  = X1 Laser Interface - Pin Assignment =
29 29  
27 +(% class="table-condensed table-striped" %)
30 30  |**Pin(s)**|**Signal**|**Manual description / use**
31 31  |1-2|Emergency-stop circuit 1|External wiring through a safety module required
32 32  |3-4|Emergency-stop circuit 2|External wiring through a safety module required