1 +**Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
2 +
3 +(% class="box errormessage" %)
4 +(((
5 +**Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.
6 +)))
7 +
8 +----
9 +
10 += Connection Locations =
11 +
12 +X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
13 +
14 +[[image:1788847354911-289.png]]
15 +
16 +
17 += X0 Mains Supply =
18 +
19 +The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
20 +
21 +(% class="box warningmessage" %)
22 +(((
23 +**Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
24 +)))
25 +
26 +
1788847354911-289.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +278.1 KB
Content
1788848413333-368.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +39.1 KB
Content
1788848413336-918.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +14.1 KB
Content
image-20260908090217-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +278.1 KB
Content