Changes for page Safety Instructions
Last modified by jadomatis on 2025/09/26 13:06
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - LaserMarking Machines.Schilling Marking Systems Multi-Light.WebHome1 +Main.WebHome - Content
-
... ... @@ -1,1 +1,82 @@ 1 -The Multi-Light Laser Marking machine encloses a Class 4 laser in a Class 1 protective cabin. As long as the cabin and interlocks are intact, harmful radiation is contained. If the protective cabin or viewing 1 +The Multi-Light Laser Marking machine encloses a** Class 4 **laser in a** Class 1** protective cabin. As long as the cabin and interlocks are intact, harmful radiation is contained. 2 + 3 +(% class="box warningmessage" %) 4 +((( 5 +**WARNING: If the protective cabin or viewing glass is damaged, stop operation immediately and contact Schilling services at: +49 (07461) 9472-16 or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]** 6 +))) 7 + 8 += Laser Classification = 9 + 10 +Accident-prevention rules classify lasers from** Class 1** (safe under reasonable foreseeable conditions) to **Class 4 **(very hazardous; even diffuse reflections can be dangerous; potential fire/explosion risk). Multi-Light uses a **1064nm, invisible** laser source - direct exposure can damage the retina and cause skin burns. 11 + 12 + 13 += Essential Operator Responsibilities = 14 + 15 +For operating a Class 4 laser (within a Class 1 enclosure), observe the following measures: 16 + 17 +* Appoint a **trained Laser Safety Officer** per BGV B 2 "Laser Radiation". 18 +* **Mark the hazard area** externally with warning lights/signs; **secure against unauthorized access**. 19 +* When work requires entry into the hazard area (e.g., service with safeguards disabled, **wear laser safety eyewear matched to wavelength and power**. 20 +* Provide a **visible emission warning light** to alert the operator to laser emission. 21 +**Note**: Compliance with these points does not replace fulfilling all applicable standards and regulations. 22 + 23 +**Standards & Regulations (selection)**: EN 60825-1, EN 60950, EN 61010-1, BGV B2/VBG93, UL 6050, UL 31011-1, 21 CFR 1040.10/1040.11. Local/regional rules may differ; the customer is responsible for implementing all safety requirements. 24 + 25 + 26 += General Safety Notes = 27 + 28 +Anyone tasked with installation, commissioning, operation, maintenance or repair must** read and understand the manual-especially the Safety chapter**. Define responsibilities clearly; electrical work may only be performed by qualified specialists. Follow all specified **power-down/isolation procedures** for setup, operation change, maintenance, inspection, and repairs. 29 + 30 +=== For the user company/ operating personnel === 31 + 32 +* **Do not perform any action that compromises machine safety**. 33 +* Prevent **unauthorized persons** from operating the system. 34 +* **Before each shift**, check for visible damage/changes affecting safety and report immediately. 35 +* Keep the machine and surrounding area **clean and orderly**; **never remove or bypass safety devices**. If removal is required for setup/repair, **reinstall immediately after**. 36 +* Setup, changeover, workpiece change, maintenance, and inspection must be done **powered-off by trained personnel**. **Unauthorized modifications are prohibited**. 37 + 38 + 39 + 40 += Laser-Specific Warnings = 41 + 42 +* **Never aim the beam at people or animals**. 43 +* **Do not manipulate or disable** interlocks or protective covers. 44 +* **Do not disassemble or modify** the laser/system; do not operate a modified system. 45 +* Using controls/procedures nor specified can cause **hazardous exposure**. 46 + 47 +Warning and information labels are placed at potential hazard points. Replace missing/damaged labels immediately. 48 + 49 + 50 += Typical Hazards and How to Prevent Them = 51 + 52 +* **Improper operation** can cause injury or machine damage - train personnel, document residual risks, follow accident-prevention rules. 53 +* **Missing**/**defective**/**bypassed safety devices** can lead to severe injury or death - check proper function and initiate corrective active immediately if faults occur. 54 +* **Misoperation during setup** - read and follow the manual before commissioning. **Never leave the machine unattended during operation; switch off main power when not in use**. 55 +* **Detached machine labels** - replace to avoid misoperation. 56 +* **Unrectifiable fault** - switch off and contact customer service. **Use original spare parts only**, non-original parts invalidate CE conformity and compromise safety. 57 + 58 + 59 + 60 += Fumes, Dusts, and By-Products = 61 + 62 +Laser processing can generate **gases**, **vapors**, **aerosols**, and **dusts**, which may be **toxic **depending on the material. Provide **suitable extraction** and comply with relevant environmental/health regulations to avoid hazards to people or the environment. Conductive dusts can enter electrical systems and cause** short circuits**, posing personnel and property damage risks. 63 + 64 + 65 += Fire and Explosion Risk = 66 + 67 +**Class 4 laser radiation** can ignite materials or cause explosions. To reduce risk: 68 + 69 +* Choose parameters to **avoid excessive heating**. 70 +* **Monitor **the system where necessary. 71 +* **Extract dust safely**; do no allow flammable residues to accumulate in the work area. 72 + 73 + 74 + 75 += Protective Devices and Emergency Measures = 76 + 77 +The system is equipped with **safety interlocks**, **protective cladding**, **laser-rated viewing glass**, and **emergency stop**. Opening the protective door prevents marking; the pilot (positioning) laser may remain active for alignment. Triggering **EMERGENCY-STOP** interrupts emission and stops all motion. **Do not operate** with damaged seals or viewing glass. 78 + 79 + 80 += Environmental and Pre-Start Checks = 81 + 82 +Before switching on: verify **electrical installation**, **input voltage**, **clean optics**, remove the** lens cover**, confirm ambient conditions, and ensure all laser safety measures are in place. The system may only be switched on after an authorized person has confirmed compliance.