Changes for page Safety Instructions

Last modified by jadomatis on 2025/09/26 13:06

From version 1.1
edited by jadomatis
on 2025/09/26 06:53
Change comment: There is no comment for this version
To version 1.12
edited by jadomatis
on 2025/09/26 07:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,1 +1,28 @@
1 -The Multi-Light Laser Marking machine encloses a Class 4 laser
1 +The Multi-Light Laser Marking machine encloses a Class 4 laser in a Class 1 protective cabin. As long as the cabin and interlocks are intact, harmful radiation is contained.
2 +
3 +(% class="box warningmessage" %)
4 +(((
5 +**WARNING: If the protective cabin or viewing glass is damaged, stop operation immediately and contact Schilling services at: +49 (07461) 9472-16 or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]**
6 +)))
7 +
8 += Laser Classification =
9 +
10 +Accident-prevention rules classify lasers from Class 1 (safe under reasonable foreseeable conditions) to Class 4 (very hazardous; even diffuse reflections can be dangerous; potential fire/explosion risk). Multi-Light uses a 1064nm, invisible laser source - direct exposure can damage the retina and cause skin burns.
11 +
12 +
13 += Essential Operator Responsibilities =
14 +
15 +For operating a Class 4 laser (within a Class 1 enclosure), observe the following measures:
16 +
17 +* Appoint a trained Laser Safety Officer per BGV B 2 "Laser Radiation".
18 +* Mark the hazard area externally with warning lights/signs; secure against unauthorized access.
19 +* When work requires entry into the hazard area (e.g., service with safeguards disabled, wear laser safety eyewear matched to wavelength and power.
20 +* Provide a visible emission warning light to alert the operator to laser emission.
21 +**Note**: Compliance with these points does not replace fulfilling all applicable standards and regulations.
22 +
23 +**Standards & Regulations (selection)**: EN 60825-1, EN 60950, EN 61010-1, BGV B2/VBG93, UL 6050, UL 31011-1, 21 CFR 1040.10/1040.11. Local/regional rules may differ; the customer is responsible for implementing all safety requirements.
24 +
25 +
26 += General Safety Notes =
27 +
28 +Anyone tasked with installation, commissioning, operation, maintenance or repair must read and understand the manual-especially the Safety chapter. Define responsibilities clearly; electrical work may only be performed by qualified specialists. Follow all specified