... ... @@ -85,6 +85,21 @@
85 85  
86 86  
87 87  
88 += Method Applicability =
89 +
90 +(% class="table-condensed table-striped" %)
91 +|=Marking method|=(% style="width: 141px;" %)Multi-Light|=(% style="width: 136px;" %)Multi-Light PLUS|=(% style="width: 136px;" %)Auto-Light|=(% style="width: 126px;" %)High-Light|=(% style="width: 441px;" %)Important difference
92 +|Engraving|(% style="width:141px" %)Supported|(% style="width:136px" %)Supported|(% style="width:136px" %)Supported|(% style="width:126px" %)Supported|(% style="width:441px" %)Achievable depth and heat input depend on power, pulse behavior, lens, and laser source. High-Light UV and UKP results must be qualified separately from fiber engraving.
93 +|Annealing|(% style="width:141px" %)Supported on suitable steel and titanium|(% style="width:136px" %)Same process|(% style="width:136px" %)Same process|(% style="width:126px" %)Source-depended|(% style="width:441px" %)
94 +|Carbonization|(% style="width:141px" %)Supported on compatible light plastics|(% style="width:136px" %)Same process|(% style="width:136px" %)Same process|(% style="width:126px" %)Source-depended|(% style="width:441px" %)
95 +|Foaming|(% style="width:141px" %)Supported on compatible dark plastics|(% style="width:136px" %)Same process|(% style="width:136px" %)Same process|(% style="width:126px" %)Source-depended|(% style="width:441px" %)
96 +|Layer removal|(% style="width:141px" %)Supported|(% style="width:136px" %)Same process with  greater workpiece capacity|(% style="width:136px" %)Same process in the integrated host machine|(% style="width:126px" %)Source-depended|(% style="width:441px" %)
97 +|Foil application|(% style="width:141px" %)Supported|(% style="width:136px" %)Supported|(% style="width:136px" %)Supported|(% style="width:126px" %)Supported with a suitable source|(% style="width:441px" %)
98 +|Ablation foil marking and cutting|(% style="width:141px" %)Accessory-depended|(% style="width:136px" %)Accessory-depended|(% style="width:136px" %)Accessory-depended|(% style="width:126px" %)Accessory-depended|(% style="width:441px" %)
99 +
100 +
101 +
102 +
88 88  = Good Practices Across All Methods =
89 89  