Version 18.10 by jadomatis on 2025/10/15 09:33

Hide last authors
jadomatis 14.2 1 The Multi-Light laser marking machine combines compact design with robust performance. This section provides the key technical specifications to help operators and engineers understand its capabilities and requirements.
2
3 ----
4
5 = General Data =
6
7 * **Laser Class**: Class 1
8 * **Available Laser Sources**: 
9 ** **F-Series **(Pulsed fiber): F20, F30, F50
10 ** **M-Series **(Pulsed MOPA fiber): M20, M30
11 * **Marking Field **(standard): 110 x 110 mm
12 * **Marking Methods Supported**: Engraving, annealing, carbonization, foaming, ablations, foils
13
14 = Dimensions and Weight =
15
16 [[**Side View 1**>>image:1758793450165-790.png||data-xwiki-image-style-alignment="start" height="239" width="221"]]
17
18 [[**Side View 2**>>image:1758793824958-446.png||data-xwiki-image-style-alignment="end" height="229" width="152"]]
19
20 * **Protective Cabin**: 603 x 505 x 837 mm
21 * **Weight: approx**. 85kg
22 * **Overall Envelope**: ~~646.5 x 518.5 x 838.6 mm(((
23 [[**Front View**>>image:1758793990318-888.png||data-xwiki-image-style-alignment="center" height="281" width="189"]]
24 )))
25
26 = Controls and Software =
27
jadomatis 17.1 28 * **Control software**: Delivered with **AnyMarker Designer**
jadomatis 14.2 29 * **Pilot laser**: Integrated red-light for positioning
30 * **Axis control**:  Automatic Z-axis for simplified setup
31
32 = Power Supply =
33
34 * **Electrical connection**: 230 V AC (standard main supply)
35 * **Power consumption**: Approx. 800-1000 W (depending on configuration)
36
37 = Operating Conditions =
38
39 * **Ambient temperature**: +15C to +30C
40 * **Relative humidity**:  Max. 70% non-condensing
41 * **Ventilation**: Operation requires a suitable exhaust system for gases and fumes
42
43 = Applications =
44
45 The Multi-Light is suitable for:
46
47 * **Engraving**
48 * **Carbonizing**
49 * **Annealing**
50 * **Layer removal**
51 * **Foaming**
52 * **Foil marking**
53
54 It can be used on metals, plastic, foils, and coated surfaces.
55
56 = Data Sheet =
57
58 [[image:1758799814911-365.png]]
jadomatis 18.2 59 \\
jadomatis 14.2 60
jadomatis 18.8 61 |=Multi-Light|=(% style="width: 139px;" %)Measuring Unit|=(% style="width: 246px;" %)F20|=F30|=F50|=M20|=M30
jadomatis 18.10 62 |=Laser source|(% style="width:139px" %) |(% colspan="3" rowspan="1" style="width:851px" %)Pulsed fiber laser|(% colspan="2" rowspan="1" %)
jadomatis 18.8 63 |=Rated power|(% style="width:139px" %)W|(% style="width:246px" %) | | | |
64 |=Pulse energy|(% style="width:139px" %)mJ|(% colspan="3" rowspan="1" style="width:851px" %) | |
65 |=Beam quality|(% style="width:139px" %) |(% colspan="2" rowspan="1" style="width:804px" %) | |(% colspan="2" rowspan="1" %)
66 |=Wavelength|(% style="width:139px" %)nm|(% colspan="5" rowspan="1" style="width:946px" %)
67 |=Pulse rate|(% style="width:139px" %)kHz|(% style="width:246px" %) | | |(% colspan="2" rowspan="1" %)
68 |=Cooling|(% style="width:139px" %) |(% colspan="5" rowspan="1" style="width:946px" %)
69 |=Power consumption|(% style="width:139px" %)W|(% style="width:246px" %) | | | |
70 |=Pulse length|(% style="width:139px" %)ns|(% style="width:246px" %) | | | |
71 |=Fiber length|(% style="width:139px" %)m|(% colspan="5" rowspan="1" style="width:246px" %)
jadomatis 18.9 72 |=(% colspan="1" rowspan="3" %)(((
73
74
75 Objective
76 )))|(% colspan="1" rowspan="3" style="width:139px" %) |(% colspan="5" rowspan="1" style="width:246px" %)
77 |(% colspan="5" rowspan="1" style="width:246px" %)
78 |(% colspan="5" rowspan="1" style="width:246px" %)
jadomatis 18.10 79 |=Max. Part size/weight |(% style="width:139px" %)mm/kg|(% colspan="5" rowspan="1" style="width:246px" %)
80 |=Protective cabin size/weight|(% style="width:139px" %)mm/kg|(% colspan="5" rowspan="1" style="width:246px" %)
81 |=Protection class|(% style="width:139px" %) |(% colspan="5" rowspan="1" style="width:246px" %)
82 |=Noise level|(% style="width:139px" %)dB|(% colspan="5" rowspan="1" style="width:246px" %)
jadomatis 18.2 83