Wiki source code of Multi-Light PLUS Technical Specifications
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | The Multi-Light PLUS is a compact, enclosed workstation for laser marking on metals, plastics, foils, and coated surfaces. It combines a robust protective housing with modern fiber-laser technology and operator friendly handling. | ||
| 2 | |||
| 3 | = Dimensions and Data Sheet = | ||
| 4 | |||
| 5 | [[image:1759471180854-365.png||height="352" width="300"]] [[image:1759471223258-418.png||height="284" width="422"]] | ||
| 6 | |||
| 7 | = Laser Source = | ||
| 8 | |||
| 9 | * **Laser type**: Pulsed fiber laser (MOPA variants available, depending on configuration) | ||
| 10 | * **Wavelength**: ~~1064 nm (near-IR) | ||
| 11 | * **Power classes**: Variant-dependent (per-rating plate/order spec) | ||
| 12 | * **Laser safety class**: **Class 4** (laser source), operated as **Class 1** due to interlocked protective housing | ||
| 13 | |||
| 14 | = Working Area = | ||
| 15 | |||
| 16 | * Standard marking field: 100 x 100 mm | ||
| 17 | * **Optional lenses**: Larger or smaller fields available; field/spot size trade-off (re-focus after lens changes) | ||
| 18 | * **Z-axis**: Automatic adjustment for focusing to different workpiece heights | ||
| 19 | * **Access**: Interlocked front door with laser-rater viewing window (Class 1 operation) | ||
| 20 | |||
| 21 | = Control and Software = | ||
| 22 | |||
| 23 | * **Software**: Delivered with EZCAD (another software solution is AnyMarker Designer) | ||
| 24 | * **Pilot laser**: Integrated (positioning outline preview) | ||
| 25 | * **Axis control**: Automatic Z-axis for fast, repeatable focusing. | ||
| 26 | |||
| 27 | = Power Supply = | ||
| 28 | |||
| 29 | * **Electrical connection**: Per rating plate (voltage/frequency); connect only with main switch OFF and verified cabling | ||
| 30 | * **Cooling**: Forced-air; keep intake/exhaust paths unobstructed; replace filter mats when soiled to prevent heat build-up | ||
| 31 | |||
| 32 | = Operating Conditions = | ||
| 33 | |||
| 34 | * **Ambient temperature**: +15C to +35C | ||
| 35 | * **Relative humidity**: <90% non-condensing | ||
| 36 | * Allow the system to acclimatize after major temperature changes before start-up | ||
| 37 | * Provide fume/dust extraction to remove gases, vapors, aerosols, and dust - this protects personnel and the working optics from deposits. | ||
| 38 | |||