1 -The Multi-Light PLUS is a compact, enclosed workstation for laser marking on metals, plastics, foils, and coated surfaces. It combines a robust protective housing with modern fiber-laser technology and operator friendly handling.
2 -
3 -= Dimensions and Data Sheet =
4 -
5 -[[image:1759471180854-365.png||height="352" width="300"]] [[image:1759471223258-418.png||height="284" width="422"]]
6 -
7 -= Laser Source =
8 -
9 -* **Laser type**: Pulsed fiber laser (MOPA variants available, depending on configuration)
10 -* **Wavelength**: ~~1064 nm (near-IR)
11 -* **Power classes**: Variant-dependent (per-rating plate/order spec)
12 -* **Laser safety class**: **Class 4** (laser source), operated as **Class 1** due to interlocked protective housing
13 -
14 -= Working Area =
15 -
16 -* Standard marking field: 100 x 100 mm
17 -* **Optional lenses**: Larger or smaller fields available; field/spot size trade-off (re-focus after lens changes)
18 -* **Z-axis**: Automatic adjustment for focusing to different workpiece heights
19 -* **Access**: Interlocked front door with laser-rater viewing window (Class 1 operation)
20 -
21 -= Control and Software =
22 -
23 -* **Software**: Delivered with EZCAD (another software solution is AnyMarker Designer)
24 -* **Pilot laser**: Integrated (positioning outline preview)
25 -* **Axis control**: Automatic Z-axis for fast, repeatable focusing.
26 -
27 -= Power Supply =
28 -
29 -* **Electrical connection**: Per rating plate (voltage/frequency); connect only with main switch OFF and verified cabling
30 -* **Cooling**: Forced-air; keep intake/exhaust paths unobstructed; replace filter mats when soiled to prevent heat build-up
31 -
32 -= Operating Conditions =
33 -
34 -* **Ambient temperature**: +15C to +35C
35 -* **Relative humidity**: <90% non-condensing
36 -* Allow the system to acclimatize after major temperature changes before start-up
37 -* Provide fume/dust extraction to remove gases, vapors, aerosols, and dust - this protects personnel and the working optics from deposits.
38 -
39 -= Data Sheet =
40 -
41 -[[image:1759473388443-964.png||height="311" width="595"]]