1 +The Multi-Light PLUS is a compact, enclosed workstation for laser marking on metals, plastics, foils, and coated surfaces. It combines a robust protective housing with modern fiber-laser technology and operator friendly handling.
2 +
3 += Dimensions and Data Sheet =
4 +
5 +[[image:1759471180854-365.png||height="352" width="300"]] [[image:1759471223258-418.png||height="284" width="422"]]
6 +
7 += Laser Source =
8 +
9 +* **Laser type**: Pulsed fiber laser (MOPA variants available, depending on configuration)
10 +* **Wavelength**: ~~1064 nm (near-IR)
11 +* **Power classes**: Variant-dependent (per-rating plate/order spec)
12 +* **Laser safety class**: **Class 4** (laser source), operated as **Class 1** due to interlocked protective housing
13 +
14 += Working Area =
15 +
16 +* Standard marking field: 100 x 100 mm
17 +* **Optional lenses**: Larger or smaller fields available; field/spot size trade-off (re-focus after lens changes)
18 +* **Z-axis**: Automatic adjustment for focusing to different workpiece heights
19 +* **Access**: Interlocked front door with laser-rater viewing window (Class 1 operation)
20 +
21 += Control and Software =
22 +
23 +* **Software**: Delivered with EZCAD (another software solution is AnyMarker Designer)
24 +* **Pilot laser**: Integrated (positioning outline preview)
25 +* **Axis control**: Automatic Z-axis for fast, repeatable focusing.
26 +
27 += Power Supply =
28 +
29 +* **Electrical connection**: Per rating plate (voltage/frequency); connect only with main switch OFF and verified cabling
30 +* **Cooling**: Forced-air; keep intake/exhaust paths unobstructed; replace filter mats when soiled to prevent heat build-up
31 +
32 += Operating Conditions =
33 +
34 +* **Ambient temperature**: +15C to +35C
35 +* **Relative humidity**: <90% non-condensing
36 +* Allow the system to acclimatize after major temperature changes before start-up
37 +* Provide fume/dust extraction to remove gases, vapors, aerosols, and dust - this protects personnel and the working optics from deposits.
38 +