The Multi-Light and Multi-Light PLUS are enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
Safety Devices
The Multi-Light includes the following safeguards:
- Main power switch
- Emergency-Stop button on the operator panel
- Door interlock switches
- Laser-rated viewing window
- Protective cladding panels and perimeter seals
Door Interlock (Cabin Door)
- The closed position of the front door is monitored by safety switches.
- With the door open, marking is inhibited; the pilot laser can remain active for alignment.
Emergency-Stop
- Located on the operator panel.
- On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
- A fault message indicates that E-Stop has been triggered; reset before resuming.
Status Indicators
On the front panel you will typically see status LEDs and an acknowledge button:
- System ready (green)
- Door closed/ready to mark (yellow)
- Laser active (red)
- Acknowledge button (blue) for initial enabling after power-on
If the system waits for acknowledge, press the blue button. If yellow is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
What the System Will not Tolerate
- Bypassed interlocks, missing cladding, or damaged viewing glass.
- Operation with compromised seals. Replace seals before use.
- Any modification that affects the protective cabin - this voids Class 1 operation.