The Multi-Light is an enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
Front Cabinet and Viewing Window Picture

Safety Devices
The Multi-Light includes the following safeguards:
- Main power switch
- Emergency-Stop button
- Door interlock switches
- Laser-rated viewing window
- Protective cladding panels
Door Interlock (Cabin Door)
- The closed position of the front door is monitored by safety switches.
- With the door open, marking is inhibited; the pilot laser can remain active for allignmen