... ... @@ -1,16 +1,21 @@
1 -The Multi-Light and Multi-Light PLUS are enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
1 +The Multi-Light is an enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
2 2  
3 3  
4 += Front Cabinet and Viewing Window Picture =
4 4  
6 +[[image:1759296146705-638.png||height="330" width="538"]]
7 +
8 +
9 +
5 5  = Safety Devices =
6 6  
7 7  The Multi-Light includes the following safeguards:
8 8  
9 -* **Main power switch**
10 -* **Emergency-Stop button **on the operator panel
11 -* **Door interlock switches**
12 -* **Laser-rated viewing window**
13 -* **Protective cladding panels **and **perimeter seals**
14 +* Main power switch
15 +* Emergency-Stop button
16 +* Door interlock switches
17 +* Laser-rated viewing window
18 +* Protective cladding panels
14 14  
15 15  (% class="box warningmessage" %)
16 16  (((
... ... @@ -21,37 +21,4 @@
21 21  
22 22  = Door Interlock (Cabin Door) =
23 23  
24 -* The **closed position** of the front door is monitored by safety switches.
25 -* With the door **open**, marking is **inhibited**; the **pilot laser** can remain active for alignment.
26 -
27 -
28 -
29 -= Emergency-Stop =
30 -
31 -* Located on the operator panel.
32 -* On activation, the **power circuit is interrupted**: laser emission is blocked by the shutter, and **all motion stops**.
33 -* A fault message indicates that E-Stop has been triggered; reset before resuming.
34 -
35 -
36 -
37 -= Status Indicators =
38 -
39 -On the front panel you will typically see status LEDs and an acknowledge button:
40 -
41 -* **System ready (green)**
42 -* **Door closed/ready to mark (yellow)**
43 -* **Laser active (red)**
44 -* **Acknowledge button (blue)** for initial enabling after power-on
45 -
46 -If the system **waits for acknowledge**, press the **blue button**. If **yellow **is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
47 -
48 -
49 -= What the System Will not Tolerate =
50 -
51 -* **Bypassed interlocks**, **missing cladding**, or **damaged viewing glass**.
52 -* Operation with **compromised seals**. Replace seals before use.
53 -* Any modification that affects the protective cabin - this **voids Class 1 operation**.
54 -