Summary

Details

Page properties
Content
... ... @@ -21,29 +21,3 @@
21 21  (((
22 22  All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.**
23 23  )))
24 -
25 -
26 -
27 -= Door Interlock (Cabin Door) =
28 -
29 -* The closed position of the front door is monitored by safety switches.
30 -* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
31 -
32 -
33 -
34 -= Emergency-Stop =
35 -
36 -* Located on the operator panel.
37 -* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
38 -* A fault message indicates that E-Stop has been triggered; reset before resuming.
39 -
40 -
41 -
42 -= Status Indicators =
43 -
44 -On the front panel you will typically see status LEDs and an acknowledge button:
45 -
46 -* System ready (green)
47 -* Door closed/ready to mark (yellow)
48 -* Laser active (red)
49 -* Acknowledge button (blue) for initial