... ... @@ -26,4 +26,37 @@
26 26  
27 27  = Door Interlock (Cabin Door) =
28 28  
29 +* The closed position of the front door is monitored by safety switches.
30 +* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
31 +
32 +
33 +
34 += Emergency-Stop =
35 +
36 +* Located on the operator panel.
37 +* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
38 +* A fault message indicates that E-Stop has been triggered; reset before resuming.
39 +
40 +
41 +
42 += Status Indicators =
43 +
44 +On the front panel you will typically see status LEDs and an acknowledge button:
45 +
46 +* System ready (green)
47 +* Door closed/ready to mark (yellow)
48 +* Laser active (red)
49 +* Acknowledge button (blue) for initial enabling after power-on
50 +
51 +If the system waits for acknowledge, press the blue button. If yellow is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
52 +
53 +
54 += What the System Will not Tolerate =
55 +
56 +* Bypassed interlock, missing cladding, or damaged viewing glass.
57 +* Operation with compromised seals. Replace seals before use.
58 +* Any modification that affects the protective cabin - this voids Class 1 operation.
59 +
60 +
61 +
29 29