Last modified by jadomatis on 2025/10/06 08:08

From version 4.3
edited by jadomatis
on 2025/10/01 07:38
Change comment: There is no comment for this version
To version 5.1
edited by jadomatis
on 2025/10/01 08:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,18 +6,56 @@
6 6  [[image:1759296146705-638.png||height="330" width="538"]]
7 7  
8 8  
9 -
10 10  = Safety Devices =
11 11  
12 12  The Multi-Light includes the following safeguards:
13 13  
14 -* Main power switch
15 -* Emergency-Stop button
16 -* Door interlock switches
17 -* Laser-rated viewing window
18 -* Protective cladding panels
13 +* **Main power switch**
14 +* **Emergency-Stop button **on the operator panel
15 +* **Door interlock switches**
16 +* **Laser-rated viewing window**
17 +* **Protective cladding panels **and **perimeter seals**
19 19  
20 20  (% class="box warningmessage" %)
21 21  (((
22 22  All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.**
23 23  )))
23 +
24 +
25 +
26 += Door Interlock (Cabin Door) =
27 +
28 +* The **closed position** of the front door is monitored by safety switches.
29 +* With the door **open**, marking is **inhibited**; the **pilot laser** can remain active for alignment.
30 +
31 +
32 +
33 += Emergency-Stop =
34 +
35 +* Located on the operator panel.
36 +* On activation, the **power circuit is interrupted**: laser emission is blocked by the shutter, and **all motion stops**.
37 +* A fault message indicates that E-Stop has been triggered; reset before resuming.
38 +
39 +
40 +
41 += Status Indicators =
42 +
43 +On the front panel you will typically see status LEDs and an acknowledge button:
44 +
45 +* **System ready (green)**
46 +* **Door closed/ready to mark (yellow)**
47 +* **Laser active (red)**
48 +* **Acknowledge button (blue)** for initial enabling after power-on
49 +
50 +If the system **waits for acknowledge**, press the **blue button**. If **yellow **is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
51 +
52 +
53 += What the System Will not Tolerate =
54 +
55 +* **Bypassed interlocks**, **missing cladding**, or **damaged viewing glass**.
56 +* Operation with **compromised seals**. Replace seals before use.
57 +* Any modification that affects the protective cabin - this **voids Class 1 operation**.
58 +
59 +
60 +
61 +