... ... @@ -21,3 +21,29 @@
21 21  (((
22 22  All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.**
23 23  )))
24 +
25 +
26 +
27 += Door Interlock (Cabin Door) =
28 +
29 +* The closed position of the front door is monitored by safety switches.
30 +* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
31 +
32 +
33 +
34 += Emergency-Stop =
35 +
36 +* Located on the operator panel.
37 +* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
38 +* A fault message indicates that E-Stop has been triggered; reset before resuming.
39 +
40 +
41 +
42 += Status Indicators =
43 +
44 +On the front panel you will typically see status LEDs and an acknowledge button:
45 +
46 +* System ready (green)
47 +* Door closed/ready to mark (yellow)
48 +* Laser active (red)
49 +* Acknowledge button (blue) for initial