Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2025/10/06 08:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,5 +19,26 @@ 19 19 20 20 (% class="box warningmessage" %) 21 21 ((( 22 -All cladding panels must 22 +All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.** 23 23 ))) 24 + 25 + 26 + 27 += Door Interlock (Cabin Door) = 28 + 29 +* The closed position of the front door is monitored by safety switches. 30 +* With the door open, marking is inhibited; the pilot laser can remain active for alignment. 31 + 32 + 33 + 34 += Emergency-Stop = 35 + 36 +* Located on the operator panel. 37 +* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops. 38 +* A fault message indicates that E-Stop has been triggered; reset before resuming. 39 + 40 + 41 + 42 += Status Indicators = 43 + 44 +