Last modified by jadomatis on 2025/10/06 08:08

From version 4.13
edited by jadomatis
on 2025/10/01 08:34
Change comment: There is no comment for this version
To version 6.1
edited by jadomatis
on 2025/10/06 08:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Laser Marking Machines.Schilling Marking Systems Multi-Light.Overview.WebHome
1 +Laser Marking Machines.Overview.WebHome
Content
... ... @@ -1,21 +1,16 @@
1 -The Multi-Light is an enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
1 +The Multi-Light and Multi-Light PLUS are enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use.
2 2  
3 3  
4 -= Front Cabinet and Viewing Window Picture =
5 5  
6 -[[image:1759296146705-638.png||height="330" width="538"]]
7 -
8 -
9 -
10 10  = Safety Devices =
11 11  
12 12  The Multi-Light includes the following safeguards:
13 13  
14 14  * **Main power switch**
15 -* **Emergency-Stop button**
10 +* **Emergency-Stop button **on the operator panel
16 16  * **Door interlock switches**
17 17  * **Laser-rated viewing window**
18 -* **Protective cladding panels**
13 +* **Protective cladding panels **and **perimeter seals**
19 19  
20 20  (% class="box warningmessage" %)
21 21  (((
... ... @@ -24,10 +24,11 @@
24 24  
25 25  
26 26  
22 +
27 27  = Door Interlock (Cabin Door) =
28 28  
29 -* The closed position of the front door is monitored by safety switches.
30 -* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
25 +* The **closed position** of the front door is monitored by safety switches.
26 +* With the door **open**, marking is **inhibited**; the **pilot laser** can remain active for alignment.
31 31  
32 32  
33 33  
... ... @@ -34,7 +34,7 @@
34 34  = Emergency-Stop =
35 35  
36 36  * Located on the operator panel.
37 -* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
33 +* On activation, the **power circuit is interrupted**: laser emission is blocked by the shutter, and **all motion stops**.
38 38  * A fault message indicates that E-Stop has been triggered; reset before resuming.
39 39  
40 40  
... ... @@ -53,9 +53,9 @@
53 53  
54 54  = What the System Will not Tolerate =
55 55  
56 -* Bypassed interlock, missing cladding, or damaged viewing glass.
57 -* Operation with compromised seals. Replace seals before use.
58 -* Any modification that affects the protective cabin - this voids Class 1 operation.
52 +* **Bypassed interlocks**, **missing cladding**, or **damaged viewing glass**.
53 +* Operation with **compromised seals**. Replace seals before use.
54 +* Any modification that affects the protective cabin - this **voids Class 1 operation**.
59 59  
60 60  
61 61