Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Laser Marking Machines.Schilling Marking Systems Multi-Light.Overview.WebHome
1 +Laser Marking Machines.Overview.WebHome
Content
... ... @@ -6,16 +6,15 @@
6 6  [[image:1759296146705-638.png||height="330" width="538"]]
7 7  
8 8  
9 -
10 10  = Safety Devices =
11 11  
12 12  The Multi-Light includes the following safeguards:
13 13  
14 -* Main power switch
15 -* Emergency-Stop button
16 -* Door interlock switches
17 -* Laser-rated viewing window
18 -* Protective cladding panels
13 +* **Main power switch**
14 +* **Emergency-Stop button **on the operator panel
15 +* **Door interlock switches**
16 +* **Laser-rated viewing window**
17 +* **Protective cladding panels **and **perimeter seals**
19 19  
20 20  (% class="box warningmessage" %)
21 21  (((
... ... @@ -26,8 +26,8 @@
26 26  
27 27  = Door Interlock (Cabin Door) =
28 28  
29 -* The closed position of the front door is monitored by safety switches.
30 -* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
28 +* The **closed position** of the front door is monitored by safety switches.
29 +* With the door **open**, marking is **inhibited**; the **pilot laser** can remain active for alignment.
31 31  
32 32  
33 33  
... ... @@ -34,7 +34,7 @@
34 34  = Emergency-Stop =
35 35  
36 36  * Located on the operator panel.
37 -* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
36 +* On activation, the **power circuit is interrupted**: laser emission is blocked by the shutter, and **all motion stops**.
38 38  * A fault message indicates that E-Stop has been triggered; reset before resuming.
39 39  
40 40  
... ... @@ -43,14 +43,20 @@
43 43  
44 44  On the front panel you will typically see status LEDs and an acknowledge button:
45 45  
46 -* System ready (green)
47 -* Door closed/ready to mark (yellow)
48 -* Laser active (red)
49 -* Acknowledge button (blue) for initial enabling after power-on
45 +* **System ready (green)**
46 +* **Door closed/ready to mark (yellow)**
47 +* **Laser active (red)**
48 +* **Acknowledge button (blue)** for initial enabling after power-on
50 50  
51 -If the system waits for acknowledge, press the blue button. If yellow is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
50 +If the system **waits for acknowledge**, press the **blue button**. If **yellow **is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
52 52  
53 53  
54 54  = What the System Will not Tolerate =
55 55  
56 -* B
55 +* **Bypassed interlocks**, **missing cladding**, or **damaged viewing glass**.
56 +* Operation with **compromised seals**. Replace seals before use.
57 +* Any modification that affects the protective cabin - this **voids Class 1 operation**.
58 +
59 +
60 +
61 +