Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2025/10/06 08:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,14 +11,52 @@ 11 11 12 12 The Multi-Light includes the following safeguards: 13 13 14 -* Main power switch 15 -* Emergency-Stop button 16 -* Door interlock switches 17 -* Laser-rated viewing window 18 -* Protective cladding panels 14 +* **Main power switch** 15 +* **Emergency-Stop button **on the operator panel 16 +* **Door interlock switches** 17 +* **Laser-rated viewing window** 18 +* **Protective cladding panels **and **perimeter seals** 19 19 20 -{{info}} 21 -All cladding panels must be present and firmly attached. If panels 22 -{{/info}} 20 +(% class="box warningmessage" %) 21 +((( 22 +All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.** 23 +))) 23 23 25 + 26 + 27 += Door Interlock (Cabin Door) = 28 + 29 +* The **closed position** of the front door is monitored by safety switches. 30 +* With the door **open**, marking is **inhibited**; the **pilot laser** can remain active for alignment. 31 + 32 + 33 + 34 += Emergency-Stop = 35 + 36 +* Located on the operator panel. 37 +* On activation, the **power circuit is interrupted**: laser emission is blocked by the shutter, and **all motion stops**. 38 +* A fault message indicates that E-Stop has been triggered; reset before resuming. 39 + 40 + 41 + 42 += Status Indicators = 43 + 44 +On the front panel you will typically see status LEDs and an acknowledge button: 45 + 46 +* **System ready (green)** 47 +* **Door closed/ready to mark (yellow)** 48 +* **Laser active (red)** 49 +* **Acknowledge button (blue)** for initial enabling after power-on 50 + 51 +If the system **waits for acknowledge**, press the **blue button**. If **yellow **is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status. 52 + 53 + 54 += What the System Will not Tolerate = 55 + 56 +* Bypassed interlocks, missing cladding, or damaged viewing glass. 57 +* Operation with compromised seals. Replace seals before use. 58 +* Any modification that affects the protective cabin - this voids Class 1 operation. 59 + 60 + 61 + 24 24
- 1759296918729-842.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.2 KB - Content