Summary

Details

Page properties
Content
... ... @@ -11,14 +11,52 @@
11 11  
12 12  The Multi-Light includes the following safeguards:
13 13  
14 -* Main power switch
15 -* Emergency-Stop button
16 -* Door interlock switches
17 -* Laser-rated viewing window
18 -* Protective cladding panels
14 +* **Main power switch**
15 +* **Emergency-Stop button**
16 +* **Door interlock switches**
17 +* **Laser-rated viewing window**
18 +* **Protective cladding panels**
19 19  
20 -{{info}}
21 -All cladding panels must be present and firmly attached. If panels
22 -{{/info}}
20 +(% class="box warningmessage" %)
21 +(((
22 +All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.**
23 +)))
23 23  
25 +
26 +
27 += Door Interlock (Cabin Door) =
28 +
29 +* The closed position of the front door is monitored by safety switches.
30 +* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
31 +
32 +
33 +
34 += Emergency-Stop =
35 +
36 +* Located on the operator panel.
37 +* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
38 +* A fault message indicates that E-Stop has been triggered; reset before resuming.
39 +
40 +
41 +
42 += Status Indicators =
43 +
44 +On the front panel you will typically see status LEDs and an acknowledge button:
45 +
46 +* **System ready (green)**
47 +* **Door closed/ready to mark (yellow)**
48 +* **Laser active (red)**
49 +* **Acknowledge button (blue)** for initial enabling after power-on
50 +
51 +If the system **waits for acknowledge**, press the **blue button**. If **yellow **is off, confirm the door is fully closed; if red does not light during job, check E-Stop and door status.
52 +
53 +
54 += What the System Will not Tolerate =
55 +
56 +* Bypassed interlock, missing cladding, or damaged viewing glass.
57 +* Operation with compromised seals. Replace seals before use.
58 +* Any modification that affects the protective cabin - this voids Class 1 operation.