Last modified by jadomatis on 2025/10/06 08:08

From version 3.3
edited by jadomatis
on 2025/10/01 07:35
Change comment: There is no comment for this version
To version 4.7
edited by jadomatis
on 2025/10/01 08:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,4 +13,26 @@
13 13  
14 14  * Main power switch
15 15  * Emergency-Stop button
16 -* Door interloc
16 +* Door interlock switches
17 +* Laser-rated viewing window
18 +* Protective cladding panels
19 +
20 +(% class="box warningmessage" %)
21 +(((
22 +All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.**
23 +)))
24 +
25 +
26 +
27 += Door Interlock (Cabin Door) =
28 +
29 +* The closed position of the front door is monitored by safety switches.
30 +* With the door open, marking is inhibited; the pilot laser can remain active for alignment.
31 +
32 +
33 +
34 += Emergency-Stop =
35 +
36 +* Located on the operator panel.
37 +* On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops.
38 +* A fault message indicates that E-Stop has been triggered; reset befor
1759296918729-842.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +103.2 KB
Content