Wiki source code of System Overview and Safety Devices
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | The Multi-Light is an enclosed Class 1 laser workstation build around a Class 4 fiber laser. Safe operation relies on it's protective housing, interlocks, and clearly indicated system states. Learn about the main hardware elements and the safety devices you interact with during daily use. | ||
| 2 | |||
| 3 | |||
| 4 | = Front Cabinet and Viewing Window Picture = | ||
| 5 | |||
| 6 | [[image:1759296146705-638.png||height="330" width="538"]] | ||
| 7 | |||
| 8 | |||
| 9 | |||
| 10 | = Safety Devices = | ||
| 11 | |||
| 12 | The Multi-Light includes the following safeguards: | ||
| 13 | |||
| 14 | * Main power switch | ||
| 15 | * Emergency-Stop button | ||
| 16 | * Door interlock switches | ||
| 17 | * Laser-rated viewing window | ||
| 18 | * Protective cladding panels | ||
| 19 | |||
| 20 | (% class="box warningmessage" %) | ||
| 21 | ((( | ||
| 22 | All cladding panels must be present and **firmly attached**. If panels or seals are missing/modified, **the Class 1 protection is no longer valid - DO NOT OPERATE THE MACHINE.** | ||
| 23 | ))) | ||
| 24 | |||
| 25 | |||
| 26 | |||
| 27 | = Door Interlock (Cabin Door) = | ||
| 28 | |||
| 29 | * The closed position of the front door is monitored by safety switches. | ||
| 30 | * With the door open, marking is inhibited; the pilot laser can remain active for alignment. | ||
| 31 | |||
| 32 | |||
| 33 | |||
| 34 | = Emergency-Stop = | ||
| 35 | |||
| 36 | * Located on the operator panel. | ||
| 37 | * On activation, the power circuit is interrupted: laser emission is blocked by the shutter, and all motion stops. | ||
| 38 | * A fault message indicates that E-Stop has been triggered; reset befor |