3.1 | 1 | Learn about the **safety and information labels** on the Multi-Light and Multi-Light PLUS workstations, why they matter, and what to do if a label is missing or damaged. Keeping all labels **present and legible** is part of maintaining **Class 1 **protected operation. |
| |
1.2 | 2 | |
| 3 | |||
| |
1.3 | 4 | = Where You'll Find Labels = |
| 5 | |||
| |
3.1 | 6 | Typical location you can find labels on Multi-Light or Multi-Light PLUS are: |
| |
1.3 | 7 | |
| |
1.22 | 8 | * **Front door/Viewing window **- laser protection information. |
| 9 | * **Operator panel/Emergency-Stop** - status indicators, acknowledge button. | ||
| 10 | * **Cabin cladding and seals** - safety class, warning triangles, general notices. | ||
| 11 | * **Rating plate** - electrical data, serial number, year of manufacture, service contact. | ||
| |
1.5 | 12 | |
| 13 | |||
| 14 | |||
| |
1.6 | 15 | = What the Labels Mean = |
| 16 | |||
| |
1.23 | 17 | * **Laser class notice:** Indicates that the machine contains a **Class 4** laser source operated within a **Class 1 **protective cabin. If the protective housing or viewing glass is damaged, **stop operation immediately**. |
| |
1.22 | 18 | * **Warning triangles/Hazard pictograms:** Draw attention to laser radiation hazards, electrical hazard, or crushing risks. Follow the manual's safety instructions and local regulations. |
| |
3.1 | 19 | * **Emergency-Stop label:** Marks the red** E-Stop** on the operator panel. Pressing E-Stop **interrupts the power circuit**, the shutter blocks emission, and **all motion stops**; a fault message indicates activation. |
| |
1.23 | 20 | * **Door interlock notice:** Reminds the marking is **inhibited **when the door is open; the **pilot laser** may stay active for alignment. |
| 21 | * **Viewing window (protective glass):** Identifies the glass as **laser-rated** for the system wavelength. If scratched or cracked - **stop operation and replace**. | ||
| |
3.1 | 22 | * **Seals and cladding notices: **State that all cladding panels must be present and** firmly attached**; if panels or the **perimeter seal** are missing or modified, **Class 1 protection is no longer valid - do not operate**. |
| |
1.24 | 23 | * **Regulatory and standards panel:** Lists applicable standards (e.g., **EN 60825-1**, EN 60950, EN 61010-1, **21 CFR 1040.10/.11**). Observe national and local rules; the customer is responsible for implementing all safety measures at the site. |
| |
1.15 | 24 | |
| |
1.16 | 25 | |
| 26 | |||
| 27 | = Status Indicators Near the Panel = | ||
| 28 | |||
| |
1.24 | 29 | * **Green (system ready)** - system powered and acknowledged. |
| 30 | * **Yellow (door closed/ready to mark)** - door interlock satisfied. | ||
| 31 | * **Red (laser active)** - marking in progress. | ||
| 32 | * **Blue (acknowledge)** - press after power-on to enable the system. | ||
| 33 | **Note**: If the system waits for acknowledge, press **blue**; if **yellow **is off, check door closure; if **red **does not light during a job, check E-Stop and door. | ||
| |
1.18 | 34 | |
| |
1.19 | 35 | |
| 36 | |||
| 37 | = If Label is Missing or Illegible = | ||
| 38 | |||
| |
1.25 | 39 | * **Do not operate** the machine until the label is **replaced**. |
| |
1.19 | 40 | * Request a replacement from Schilling and record the issue. |
| |
1.25 | 41 | * Treat damaged **viewing glass**, **cladding**, or **seals **as safety-critical: **stop and service before use**. |
| |
1.19 | 42 | |
| 43 | |||
| 44 | |||
| |
1.20 | 45 | = Good Practice = |
| |
1.19 | 46 | |
| |
1.25 | 47 | * Include label checks in **daily visual inspections** (door, interlock notices, E-Stop label, window marking). |
| 48 | * Keep the front window **clean **so protection view remain clear; never scratch or polish the coating. | ||
| 49 | * After any service or transport, confirm **all labels** are present and readable before returning to operation. |