Last modified by jadomatis on 2025/10/06 07:32

From version 3.1
edited by jadomatis
on 2025/10/06 07:32
Change comment: There is no comment for this version
To version 1.22
edited by jadomatis
on 2025/10/01 12:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Laser Marking Machines.Overview.WebHome
1 +Laser Marking Machines.Schilling Marking Systems Multi-Light.Overview.WebHome
Content
... ... @@ -1,9 +1,9 @@
1 -Learn about the **safety and information labels** on the Multi-Light and Multi-Light PLUS workstations, why they matter, and what to do if a label is missing or damaged. Keeping all labels **present and legible** is part of maintaining **Class 1 **protected operation.
1 +Learn about the **safety and information labels** on the Multi-Light workstation, why they matter, and what to do if a label is missing or damaged. Keeping all labels **present and legible** is part of maintaining **Class 1 **protected operation.
2 2  
3 3  
4 4  = Where You'll Find Labels =
5 5  
6 -Typical location you can find labels on Multi-Light or Multi-Light PLUS are:
6 +Typical location you can find labels on Multi-Light are:
7 7  
8 8  * **Front door/Viewing window **- laser protection information.
9 9  * **Operator panel/Emergency-Stop** - status indicators, acknowledge button.
... ... @@ -14,36 +14,38 @@
14 14  
15 15  = What the Labels Mean =
16 16  
17 -* **Laser class notice:** Indicates that the machine contains a **Class 4** laser source operated within a **Class 1 **protective cabin. If the protective housing or viewing glass is damaged, **stop operation immediately**.
17 +* **Laser class notice:** Indicates that the machine contains a **Class 4** laser source operated within a Class 1 protective cabin. If the protective housing or viewing glass is damaged, stop operation immediately.
18 18  * **Warning triangles/Hazard pictograms:** Draw attention to laser radiation hazards, electrical hazard, or crushing risks. Follow the manual's safety instructions and local regulations.
19 -* **Emergency-Stop label:** Marks the red** E-Stop** on the operator panel. Pressing E-Stop **interrupts the power circuit**, the shutter blocks emission, and **all motion stops**; a fault message indicates activation.
20 -* **Door interlock notice:** Reminds the marking is **inhibited **when the door is open; the **pilot laser** may stay active for alignment.
21 -* **Viewing window (protective glass):** Identifies the glass as **laser-rated** for the system wavelength. If scratched or cracked - **stop operation and replace**.
22 -* **Seals and cladding notices: **State that all cladding panels must be present and** firmly attached**; if panels or the **perimeter seal** are missing or modified, **Class 1 protection is no longer valid -  do not operate**.
23 -* **Regulatory and standards panel:** Lists applicable standards (e.g., **EN 60825-1**, EN 60950, EN 61010-1, **21 CFR 1040.10/.11**). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
19 +* **Emergency-Stop label:** Marks the red E-Stop on the operator panel. Pressing E-Stop interrupts the power circuit, the shutter blocks emission, and all motion stops; a fault message indicates activation.
20 +* **Door interlock notice:** Reminds the marking is inhibited when the door is open; the pilot laser may stay active for alignment.
21 +* **Viewing window (protective glass):** Identifies the glass as laser-rated for the system wavelength. If scratched or cracked - stop operation and replace.
22 +* **Seals and cladding notices: **State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid -  do not operate.
23 +* **Regulatory and standards panel:** Lists applicable standards (e.g., EN 60825-1, EN 60950, EN 61010-1, 21 CFR 1040.10/.11). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
24 24  
25 25  
26 26  
27 27  = Status Indicators Near the Panel =
28 28  
29 -* **Green (system ready)** - system powered and acknowledged.
30 -* **Yellow (door closed/ready to mark)** - door interlock satisfied.
31 -* **Red (laser active)** - marking in progress.
32 -* **Blue (acknowledge)** - press after power-on to enable the system.
33 -**Note**: If the system waits for acknowledge, press **blue**; if **yellow **is off, check door closure; if **red **does not light during a job, check E-Stop and door.
29 +* Green (system ready) - system powered and acknowledged.
30 +* Yellow (door closed/ready to mark) - door interlock satisfied.
31 +* Red (laser active) - marking in progress.
32 +* Blue (acknowledge) - press after power-on to enable the system.
33 +Note: If the system waits for acknowledge, press blue; if yellow is off, check door closure; if red does not light during a job, check E-Stop and door.
34 34  
35 35  
36 36  
37 37  = If Label is Missing or Illegible =
38 38  
39 -* **Do not operate** the machine until the label is **replaced**.
39 +* Do not operate the machine until the label is replaced.
40 40  * Request a replacement from Schilling and record the issue.
41 -* Treat damaged **viewing glass**, **cladding**, or **seals **as safety-critical: **stop and service before use**.
41 +* Treat damaged viewing glass, cladding, or seals as safety-critical: stop and service before use.
42 42  
43 43  
44 44  
45 45  = Good Practice =
46 46  
47 -* Include label checks in **daily visual inspections** (door, interlock notices, E-Stop label, window marking).
48 -* Keep the front window **clean **so protection view remain clear; never scratch or polish the coating.
49 -* After any service or transport, confirm **all labels** are present and readable before returning to operation.
47 +* Include label checks in daily visual inspections (door, interlock notices, E-Stop label, window marking).
48 +* Keep the front window clean so protection view remain clear; never scratch or polish the coating.
49 +* After any service or transport, confirm all labels are present and readable before returning to operation.
50 +
51 +