Last modified by jadomatis on 2025/10/06 07:32

From version 1.4
edited by jadomatis
on 2025/10/01 10:33
Change comment: There is no comment for this version
To version 1.17
edited by jadomatis
on 2025/10/01 11:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,4 +8,25 @@
8 8  * Front door/Viewing window - laser protection information.
9 9  * Operator panel/Emergency-Stop - status indicators, acknowledge button.
10 10  * Cabin cladding and seals - safety class, warning triangles, general notices.
11 -* Rating plate - electrical
11 +* Rating plate - electrical data, serial number, year of manufacture, service contact.
12 +
13 +
14 +
15 += What the Labels Mean =
16 +
17 +* Laser class notice: Indicates that the machine contains a Class 4 laser source operated within a Class 1 protective cabin. If the protective housing or viewing glass is damaged, stop operation immediately.
18 +* Warning triangles/Hazard pictograms: Draw attention to laser radiation hazards, electrical hazard, or crushing risks. Follow the manual's safety instructions and local regulations.
19 +* Emergency-Stop label: Marks the red E-Stop on the operator panel. Pressing E-Stop interrupts the power circuit, the shutter blocks emission, and all motion stops; a fault message indicates activation.
20 +* Door interlock notice: Reminds the marking is inhibited when the door is open; the pilot laser may stay active for alignment.
21 +* Viewing window (protective glass): Identifies the glass as laser-rated for the system wavelength. If scratched or cracked - stop operation and replace.
22 +* Seals and cladding notices: State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid -  do not operate.
23 +* Regulatory and standards panel: Lists applicable standards (e.g., EN 60825-1, EN 60950, EN 61010-1, 21 CFR 1040.10/.11). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
24 +
25 +
26 +
27 += Status Indicators Near the Panel =
28 +
29 +* Green (system ready)
30 +* Yellow (door closed/ready to mark)
31 +* Red (laser active)
32 +* Blue (acknowledge)