... ... @@ -19,33 +19,31 @@
19 19  * **Emergency-Stop label:** Marks the red** E-Stop** on the operator panel. Pressing E-Stop **interrupts the power circuit**, the shutter blocks emission, and **all motion stops**; a fault message indicates activation.
20 20  * **Door interlock notice:** Reminds the marking is **inhibited **when the door is open; the **pilot laser** may stay active for alignment.
21 21  * **Viewing window (protective glass):** Identifies the glass as **laser-rated** for the system wavelength. If scratched or cracked - **stop operation and replace**.
22 -* **Seals and cladding notices: **State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, **Class 1 protection is no longer valid -  do not operate.**
23 -* **Regulatory and standards panel:** Lists applicable standards (e.g., EN 60825-1, EN 60950, EN 61010-1, 21 CFR 1040.10/.11). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
22 +* **Seals and cladding notices: **State that all cladding panels must be present and** firmly attached**; if panels or the **perimeter seal** are missing or modified, **Class 1 protection is no longer valid -  do not operate**.
23 +* **Regulatory and standards panel:** Lists applicable standards (e.g., **EN 60825-1**, EN 60950, EN 61010-1, **21 CFR 1040.10/.11**). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
24 24  
25 25  
26 26  
27 27  = Status Indicators Near the Panel =
28 28  
29 -* Green (system ready) - system powered and acknowledged.
30 -* Yellow (door closed/ready to mark) - door interlock satisfied.
31 -* Red (laser active) - marking in progress.
32 -* Blue (acknowledge) - press after power-on to enable the system.
33 -Note: If the system waits for acknowledge, press blue; if yellow is off, check door closure; if red does not light during a job, check E-Stop and door.
29 +* **Green (system ready)** - system powered and acknowledged.
30 +* **Yellow (door closed/ready to mark)** - door interlock satisfied.
31 +* **Red (laser active)** - marking in progress.
32 +* **Blue (acknowledge)** - press after power-on to enable the system.
33 +**Note**: If the system waits for acknowledge, press **blue**; if **yellow **is off, check door closure; if **red **does not light during a job, check E-Stop and door.
34 34  
35 35  
36 36  
37 37  = If Label is Missing or Illegible =
38 38  
39 -* Do not operate the machine until the label is replaced.
39 +* **Do not operate** the machine until the label is **replaced**.
40 40  * Request a replacement from Schilling and record the issue.
41 -* Treat damaged viewing glass, cladding, or seals as safety-critical: stop and service before use.
41 +* Treat damaged **viewing glass**, **cladding**, or **seals **as safety-critical: **stop and service before use**.
42 42  
43 43  
44 44  
45 45  = Good Practice =
46 46  
47 -* Include label checks in daily visual inspections (door, interlock notices, E-Stop label, window marking).
48 -* Keep the front window clean so protection view remain clear; never scratch or polish the coating.
49 -* After any service or transport, confirm all labels are present and readable before returning to operation.
50 -
51 -
47 +* Include label checks in **daily visual inspections** (door, interlock notices, E-Stop label, window marking).
48 +* Keep the front window **clean **so protection view remain clear; never scratch or polish the coating.
49 +* After any service or transport, confirm **all labels** are present and readable before returning to operation.