1 1  Learn about the safety and information labels on the Multi-Light workstation, why they matter, and what to do if a label is missing or damaged. Keeping all labels present and legible is part of maintaining Class 1 protected operation.
2 2  
3 3  
4 -= =
4 += Where You'll Find Labels =
5 +
6 +Typical location you can find labels on Multi-Light are:
7 +
8 +* Front door/Viewing window - laser protection information.
9 +* Operator panel/Emergency-Stop - status indicators, acknowledge button.
10 +* Cabin cladding and seals - safety class, warning triangles, general notices.
11 +* Rating plate - electrical data, serial number, year of manufacture, service contact.
12 +
13 +
14 +
15 += What the Labels Mean =
16 +
17 +* Laser class notice: Indicates that the machine contains a Class 4 laser source operated within a Class 1 protective cabin. If the protective housing or viewing glass is damaged, stop operation immediately.
18 +* Warning triangles/Hazard pictograms: Draw attention to laser radiation hazards, electrical hazard, or crushing risks. Follow the manual's safety instructions and local regulations.
19 +* Emergency-Stop label: Marks the red E-Stop on the operator panel. Pressing E-Stop interrupts the power circuit, the shutter blocks emission, and all motion stops; a fault message indicates activation.
20 +* Door interlock notice: Reminds the marking is inhibited when the door is open; the pilot laser may stay active for alignment.
21 +* Viewing window (protective glass): Identifies the glass as laser-rated for the system wavelength. If scratched or cracked - stop operation and replace.
22 +* Seals and cladding notices: State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid -  do not operate.
23 +* Regulatory and standards panel: Lists applicable standards (e.g.,