Last modified by jadomatis on 2025/10/06 07:32

From version 1.14
edited by jadomatis
on 2025/10/01 11:44
Change comment: There is no comment for this version
To version 1.19
edited by jadomatis
on 2025/10/01 12:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,4 +20,27 @@
20 20  * Door interlock notice: Reminds the marking is inhibited when the door is open; the pilot laser may stay active for alignment.
21 21  * Viewing window (protective glass): Identifies the glass as laser-rated for the system wavelength. If scratched or cracked - stop operation and replace.
22 22  * Seals and cladding notices: State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid -  do not operate.
23 -* Regulatory and standards panel: Lists applicable standards (e.g., EN 60825-1, EN 60950, EN 61010-1, 21 CFR 1040.10/.11). Observe national and local rules; the
23 +* Regulatory and standards panel: Lists applicable standards (e.g., EN 60825-1, EN 60950, EN 61010-1, 21 CFR 1040.10/.11). Observe national and local rules; the customer is responsible for implementing all safety measures at the site.
24 +
25 +
26 +
27 += Status Indicators Near the Panel =
28 +
29 +* Green (system ready) - system powered and acknowledged.
30 +* Yellow (door closed/ready to mark) - door interlock satisfied.
31 +* Red (laser active) - marking in progress.
32 +* Blue (acknowledge) - press after power-on to enable the system.
33 +Note: If the system waits for acknowledge, press blue; if yellow is off, check door closure; if red does not light during a job, check E-Stop and door.
34 +
35 +
36 +
37 += If Label is Missing or Illegible =
38 +
39 +* Do not operate the machine until the label is replaced.
40 +* Request a replacement from Schilling and record the issue.
41 +* Treat damaged viewing glass, cladding, or seals as safety-critical: stop and service before use.
42 +
43 +
44 +
45 +
46 +