Last modified by jadomatis on 2025/10/06 07:32

From version 1.13
edited by jadomatis
on 2025/10/01 11:41
Change comment: There is no comment for this version
To version 1.12
edited by jadomatis
on 2025/10/01 11:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,5 +19,4 @@
19 19  * Emergency-Stop label: Marks the red E-Stop on the operator panel. Pressing E-Stop interrupts the power circuit, the shutter blocks emission, and all motion stops; a fault message indicates activation.
20 20  * Door interlock notice: Reminds the marking is inhibited when the door is open; the pilot laser may stay active for alignment.
21 21  * Viewing window (protective glass): Identifies the glass as laser-rated for the system wavelength. If scratched or cracked - stop operation and replace.
22 -* Seals and cladding notices: State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid -  do not operate.
23 -* Regulatory and standards panel: Lists applicable standards (e.g.,
22 +* Seals and cladding notices: State that all cladding panels must be present and firmly attached; if panels or the perimeter seal are missing or modified, Class 1 protection is no longer valid 0