Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2025/10/06 07:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,4 +15,37 @@ 15 15 Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted. 16 16 17 17 18 - 18 += Laser Protection Window = 19 + 20 +What it does: Provides certified protection at the laser wavelength and allows visual monitoring. 21 +When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods. 22 + 23 + 24 += Perimeter Seals/Cladding Fasteners = 25 + 26 +What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage). 27 +When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted. 28 + 29 + 30 += Optics Care Material = 31 + 32 +What to stock: 33 + 34 +* Approved lens cleaning wipes/lint-free tissues 35 +* High-purity alcohol (>98%) for optics cleaning 36 +* Small hand air bulb (no compressed air) 37 +When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 38 + 39 + 40 + 41 += Lenses/Objectives = 42 + 43 +What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 44 +When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 45 + 46 + 47 += Service Items (performed by Schilling/authorized personnel) = 48 + 49 +Typical items listed in the service scope include: 50 + 51 +* Cleaning