Last modified by jadomatis on 2025/10/06 07:31

From version 1.6
edited by jadomatis
on 2025/10/02 07:11
Change comment: There is no comment for this version
To version 1.16
edited by jadomatis
on 2025/10/02 08:03
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,4 +11,47 @@
11 11  = Extraction System Filters =
12 12  
13 13  What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics.
14 -When to replace:
14 +When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material.
15 +Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.
16 +
17 +
18 += Laser Protection Window =
19 +
20 +What it does: Provides certified protection at the laser wavelength and allows visual monitoring.
21 +When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods.
22 +
23 +
24 += Perimeter Seals/Cladding Fasteners =
25 +
26 +What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage).
27 +When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted.
28 +
29 +
30 += Optics Care Material =
31 +
32 +What to stock:
33 +
34 +* Approved lens cleaning wipes/lint-free tissues
35 +* High-purity alcohol (>98%) for optics cleaning
36 +* Small hand air bulb (no compressed air)
37 +When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
38 +
39 +
40 +
41 += Lenses/Objectives =
42 +
43 +What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
44 +When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
45 +
46 +
47 += Service Items (performed by Schilling/authorized personnel) =
48 +
49 +Typical items listed in the service scope include:
50 +
51 +* Cleaning of fans, replacement of filter mats (key for lifetime/performance)
52 +* Cleaning of laser source and optics, laser power measurement (with protocol)
53 +* Check and corre
54 +
55 +
56 +
57 +