Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2025/10/06 07:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,67 +1,51 @@ 1 1 Learn about the typical wear parts and consumables for Multi-Light workstation and how to replace them. Always use original parts and follow the maintenance instructions in the manual. 2 2 3 + 3 3 = Filter Mat = 4 4 5 - **What it does**: Protects the electronics from dust; keeps cooling airflow stable.6 - **Location**: Behind the**front ventilation**slots of the laser plug-in unit or the PC.7 - **When to replace**: Inspect regularly;**replace when soiled**to maintain proper cooling.6 +What it does: Protects the electronics from dust; keeps cooling airflow stable. 7 +Location: Behind the front ventilation slots of the laser plug-in unit or the PC. 8 +When to replace: Inspect regularly; replace when soiled to maintain proper cooling. 8 8 9 9 10 10 = Extraction System Filters = 11 11 12 - **What do they do**: Remove**fumes**,**vapors**,**aerosols**,**and dusts**generated during marking; protect personnel and optics.13 - **When to replace**: At least**annually check the main filter**;**replace if contaminated**. Frequency depends on workload/material.14 - **Tip**: Using an extraction unit is highly recommended for**plastics**and**larger material removal**(e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.13 +What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics. 14 +When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material. 15 +Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted. 15 15 16 16 17 17 = Laser Protection Window = 18 18 19 - **What it does**: Provides certified protection at the laser wavelength and allows visual monitoring.20 - **When to replace**: If**scratched**,**cracked**, or**clouded**- stop operation and replace before further use. Clean only with approved methods.20 +What it does: Provides certified protection at the laser wavelength and allows visual monitoring. 21 +When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods. 21 21 22 22 23 23 = Perimeter Seals/Cladding Fasteners = 24 24 25 - **What they do**: Ensure the protective cabin remains**Class 1**tight (no radiation leakage).26 - **When to replace**: If**missing**,**damaged**, or**loose**. Operation with compromised seals/cladding is**not permitted**.26 +What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage). 27 +When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted. 27 27 28 28 29 29 = Optics Care Material = 30 30 31 - **What to stock**:32 +What to stock: 32 32 33 -* Approved **lens cleaning wipes**/lint-free tissues34 -* **High-purity alcohol**(>98%) for optics cleaning35 -* Small **hand air bulb**(no compressed air)36 - **When to use**: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.34 +* Approved lens cleaning wipes/lint-free tissues 35 +* High-purity alcohol (>98%) for optics cleaning 36 +* Small hand air bulb (no compressed air) 37 +When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 37 37 38 38 39 39 40 40 = Lenses/Objectives = 41 41 42 - **What they do**: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)43 - **When to replace/add**: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.43 +What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 44 +When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 44 44 45 45 46 46 = Service Items (performed by Schilling/authorized personnel) = 47 47 48 -Typical items listed in the **service scope**include:49 +Typical items listed in the service scope include: 49 49 50 -* **Cleaning **of fans, **replacement of filter mats** (key for lifetime/performance) 51 -* Cleaning of laser source and optics, **laser power measurement** (with protocol) 52 -* Check and correction of **working field** and **pilot laser **alignment. 53 -* Functional checks of **software** and **laser files**, measurement of **electrical connection** (per VDE 0701-0702), and refresher training if needed. 54 - 55 - 56 - 57 -= Replacement Laser (during repair) = 58 - 59 -Schilling can provide a **replacement laser** for the repair period to keep you productive; contact service to arrange. 60 - 61 - 62 -= Ordering and Support = 63 - 64 -For spare parts, filters, or service contact **Schilling Marking Systems GmbH **- Service : **+49 (7461) 9472-16** or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your **serial number** and** software version** ready. 65 - 66 - 67 - 51 +* Cleaning