Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2025/10/06 07:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,7 +23,7 @@ 23 23 = Perimeter Seals/Cladding Fasteners = 24 24 25 25 **What they do**: Ensure the protective cabin remains **Class 1** tight (no radiation leakage). 26 -**When to replace**: If **missing**, **damaged**, or loose. Operation with compromised seals/cladding is not permitted. 26 +**When to replace**: If **missing**, **damaged**, or **loose**. Operation with compromised seals/cladding is **not permitted**. 27 27 28 28 29 29 = Optics Care Material = ... ... @@ -30,38 +30,38 @@ 30 30 31 31 **What to stock**: 32 32 33 -* Approved lens cleaning wipes/lint-free tissues 34 -* High-purity alcohol (>98%) for optics cleaning 35 -* Small hand air bulb (no compressed air) 36 -When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 33 +* Approved **lens cleaning wipes**/lint-free tissues 34 +* **High-purity alcohol** (>98%) for optics cleaning 35 +* Small **hand air bulb** (no compressed air) 36 +**When to use**: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 37 37 38 38 39 39 40 40 = Lenses/Objectives = 41 41 42 -What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 43 -When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 42 +**What they do**: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 43 +**When to replace/add**: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 44 44 45 45 46 46 = Service Items (performed by Schilling/authorized personnel) = 47 47 48 -Typical items listed in the service scope include: 48 +Typical items listed in the **service scope** include: 49 49 50 -* Cleaning of fans, replacement of filter mats (key for lifetime/performance) 51 -* Cleaning of laser source and optics, laser power measurement (with protocol) 52 -* Check and correction of working field and pilot laser alignment. 53 -* Functional checks of software and laser files, measurement of electrical connection (per VDE 0701-0702), and refresher training if needed. 50 +* **Cleaning **of fans, **replacement of filter mats** (key for lifetime/performance) 51 +* Cleaning of laser source and optics, **laser power measurement** (with protocol) 52 +* Check and correction of **working field** and **pilot laser **alignment. 53 +* Functional checks of **software** and **laser files**, measurement of **electrical connection** (per VDE 0701-0702), and refresher training if needed. 54 54 55 55 56 56 57 57 = Replacement Laser (during repair) = 58 58 59 -Schilling can provide a replacement laser for the repair period to keep you productive; contact service to arrange. 59 +Schilling can provide a **replacement laser** for the repair period to keep you productive; contact service to arrange. 60 60 61 61 62 62 = Ordering and Support = 63 63 64 -For spare parts, filters, or service contact Schilling Marking Systems GmbH - Service : +49 (7461) 9472-16 or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your serial number and software version ready. 64 +For spare parts, filters, or service contact **Schilling Marking Systems GmbH **- Service : **+49 (7461) 9472-16** or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your **serial number** and** software version** ready. 65 65 66 66 67 67