Last modified by jadomatis on 2025/10/06 07:31

From version 1.20
edited by jadomatis
on 2025/10/02 08:25
Change comment: There is no comment for this version
To version 1.22
edited by jadomatis
on 2025/10/02 08:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -23,7 +23,7 @@
23 23  = Perimeter Seals/Cladding Fasteners =
24 24  
25 25  **What they do**: Ensure the protective cabin remains **Class 1** tight (no radiation leakage).
26 -**When to replace**: If **missing**, **damaged**, or loose. Operation with compromised seals/cladding is not permitted.
26 +**When to replace**: If **missing**, **damaged**, or **loose**. Operation with compromised seals/cladding is **not permitted**.
27 27  
28 28  
29 29  = Optics Care Material =
... ... @@ -30,38 +30,38 @@
30 30  
31 31  **What to stock**:
32 32  
33 -* Approved lens cleaning wipes/lint-free tissues
34 -* High-purity alcohol (>98%) for optics cleaning
35 -* Small hand air bulb (no compressed air)
36 -When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
33 +* Approved **lens cleaning wipes**/lint-free tissues
34 +* **High-purity alcohol** (>98%) for optics cleaning
35 +* Small **hand air bulb** (no compressed air)
36 +**When to use**: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
37 37  
38 38  
39 39  
40 40  = Lenses/Objectives =
41 41  
42 -What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
43 -When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
42 +**What they do**: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
43 +**When to replace/add**: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
44 44  
45 45  
46 46  = Service Items (performed by Schilling/authorized personnel) =
47 47  
48 -Typical items listed in the service scope include:
48 +Typical items listed in the **service scope** include:
49 49  
50 -* Cleaning of fans, replacement of filter mats (key for lifetime/performance)
51 -* Cleaning of laser source and optics, laser power measurement (with protocol)
52 -* Check and correction of working field and pilot laser alignment.
53 -* Functional checks of software and laser files, measurement of electrical connection (per VDE 0701-0702), and refresher training if needed.
50 +* **Cleaning **of fans, **replacement of filter mats** (key for lifetime/performance)
51 +* Cleaning of laser source and optics, **laser power measurement** (with protocol)
52 +* Check and correction of **working field** and **pilot laser **alignment.
53 +* Functional checks of **software** and **laser files**, measurement of **electrical connection** (per VDE 0701-0702), and refresher training if needed.
54 54  
55 55  
56 56  
57 57  = Replacement Laser (during repair) =
58 58  
59 -Schilling can provide a replacement laser for the repair period to keep you productive; contact service to arrange.
59 +Schilling can provide a **replacement laser** for the repair period to keep you productive; contact service to arrange.
60 60  
61 61  
62 62  = Ordering and Support =
63 63  
64 -For spare parts, filters, or service contact Schilling Marking Systems GmbH - Service : +49 (7461) 9472-16 or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your serial number and software version ready.
64 +For spare parts, filters, or service contact **Schilling Marking Systems GmbH **- Service : **+49 (7461) 9472-16** or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your **serial number** and** software version** ready.
65 65  
66 66  