... ... @@ -15,38 +15,4 @@
15 15  Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.
16 16  
17 17  
18 -= Laser Protection Window =
19 -
20 -What it does: Provides certified protection at the laser wavelength and allows visual monitoring.
21 -When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods.
22 -
23 -
24 -= Perimeter Seals/Cladding Fasteners =
25 -
26 -What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage).
27 -When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted.
28 -
29 -
30 -= Optics Care Material =
31 -
32 -What to stock:
33 -
34 -* Approved lens cleaning wipes/lint-free tissues
35 -* High-purity alcohol (>98%) for optics cleaning
36 -* Small hand air bulb (no compressed air)
37 -When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
38 -
39 -
40 -
41 -= Lenses/Objectives =
42 -
43 -What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
44 -When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
45 -
46 -
47 -= Service Items (performed by Schilling/authorized personnel) =
48 -
49 -Typical items listed in the service scope include:
50 -
51 -* Cleaning of fans, replacement of filter mats (key for lifetime/performance)
52 -* Cleaning of laser source and optics, laser power measurement (with protocol)
18 +