Last modified by jadomatis on 2025/10/06 07:31

From version 1.12
edited by jadomatis
on 2025/10/02 07:41
Change comment: There is no comment for this version
To version 1.20
edited by jadomatis
on 2025/10/02 08:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,27 +1,67 @@
1 1  Learn about the typical wear parts and consumables for Multi-Light workstation and how to replace them. Always use original parts and follow the maintenance instructions in the manual.
2 2  
3 -
4 4  = Filter Mat =
5 5  
6 -What it does: Protects the electronics from dust; keeps cooling airflow stable.
7 -Location: Behind the front ventilation slots of the laser plug-in unit or the PC.
8 -When to replace: Inspect regularly; replace when soiled to maintain proper cooling.
5 +**What it does**: Protects the electronics from dust; keeps cooling airflow stable.
6 +**Location**: Behind the **front ventilation** slots of the laser plug-in unit or the PC.
7 +**When to replace**: Inspect regularly; **replace when soiled **to maintain proper cooling.
9 9  
10 10  
11 11  = Extraction System Filters =
12 12  
13 -What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics.
14 -When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material.
15 -Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.
12 +**What do they do**: Remove **fumes**, **vapors**, **aerosols**, **and dusts** generated during marking; protect personnel and optics.
13 +**When to replace**: At least **annually check the main filter**; **replace if contaminated**. Frequency depends on workload/material.
14 +**Tip**: Using an extraction unit is highly recommended for **plastics **and **larger material removal** (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.
16 16  
17 17  
18 18  = Laser Protection Window =
19 19  
20 -What it does: Provides certified protection at the laser wavelength and allows visual monitoring.
21 -When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods.
19 +**What it does**: Provides certified protection at the laser wavelength and allows visual monitoring.
20 +**When to replace**: If **scratched**, **cracked**, or **clouded **- stop operation and replace before further use. Clean only with approved methods.
22 22  
23 23  
24 24  = Perimeter Seals/Cladding Fasteners =
25 25  
26 -What they do: Ensure the protective cabin remains Class 1 ti
27 -When to replace: If missing
25 +**What they do**: Ensure the protective cabin remains **Class 1** tight (no radiation leakage).
26 +**When to replace**: If **missing**, **damaged**, or loose. Operation with compromised seals/cladding is not permitted.
27 +
28 +
29 += Optics Care Material =
30 +
31 +**What to stock**:
32 +
33 +* Approved lens cleaning wipes/lint-free tissues
34 +* High-purity alcohol (>98%) for optics cleaning
35 +* Small hand air bulb (no compressed air)
36 +When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
37 +
38 +
39 +
40 += Lenses/Objectives =
41 +
42 +What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
43 +When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
44 +
45 +
46 += Service Items (performed by Schilling/authorized personnel) =
47 +
48 +Typical items listed in the service scope include:
49 +
50 +* Cleaning of fans, replacement of filter mats (key for lifetime/performance)
51 +* Cleaning of laser source and optics, laser power measurement (with protocol)
52 +* Check and correction of working field and pilot laser alignment.
53 +* Functional checks of software and laser files, measurement of electrical connection (per VDE 0701-0702), and refresher training if needed.
54 +
55 +
56 +
57 += Replacement Laser (during repair) =
58 +
59 +Schilling can provide a replacement laser for the repair period to keep you productive; contact service to arrange.
60 +
61 +
62 += Ordering and Support =
63 +
64 +For spare parts, filters, or service contact Schilling Marking Systems GmbH - Service : +49 (7461) 9472-16 or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your serial number and software version ready.
65 +
66 +
67 +