Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2025/10/06 07:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,5 +23,36 @@ 23 23 24 24 = Perimeter Seals/Cladding Fasteners = 25 25 26 -What they do: Ensure the protective cabin remains Class 1 ti 27 -When to replace: If missing 26 +What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage). 27 +When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted. 28 + 29 + 30 += Optics Care Material = 31 + 32 +What to stock: 33 + 34 +* Approved lens cleaning wipes/lint-free tissues 35 +* High-purity alcohol (>98%) for optics cleaning 36 +* Small hand air bulb (no compressed air) 37 +When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 38 + 39 + 40 + 41 += Lenses/Objectives = 42 + 43 +What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 44 +When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 45 + 46 + 47 += Service Items (performed by Schilling/authorized personnel) = 48 + 49 +Typical items listed in the service scope include: 50 + 51 +* Cleaning of fans, replacement of filter mats (key for lifetime/performance) 52 +* Cleaning of laser source and optics, laser power measurement (with protocol) 53 +* Check and correction of working field and pilot laser alignment. 54 +* Functional checks of software and laser files, measur 55 + 56 + 57 + 58 +