| 1 | Learn about the typical wear parts and consumables for Multi-Light workstation and how to replace them. Always use original parts and follow the maintenance instructions in the manual. | ||
| 2 | |||
| 3 | |||
| 4 | = Filter Mat = | ||
| 5 | |||
| 6 | What it does: Protects the electronics from dust; keeps cooling airflow stable. | ||
| 7 | Location: Behind the front ventilation slots of the laser plug-in unit or the PC. | ||
| 8 | When to replace: Inspect regularly; replace when soiled to maintain proper cooling. | ||
| 9 | |||
| 10 | |||
| 11 | = Extraction System Filters = | ||
| 12 | |||
| 13 | What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics. | ||
| 14 | When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material. | ||
| 15 | Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted. | ||
| 16 | |||
| 17 | |||
| 18 | = Laser Protection Window = | ||
| 19 | |||
| 20 | What it does: Provides certified protection at the laser wavelength and allows visual monitoring. | ||
| 21 | When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods. | ||
| 22 | |||
| 23 | |||
| 24 | = Perimeter Seals/Cladding Fasteners = | ||
| 25 | |||
| 26 | What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage). | ||
| 27 | When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted. | ||
| 28 | |||
| 29 | |||
| 30 | = Optics Care Material = | ||
| 31 | |||
| 32 | What to stock: | ||
| 33 | |||
| 34 | * Approved lens cleaning wipes/lint-free tissues | ||
| 35 | * High-purity alcohol (>98%) for optics cleaning | ||
| 36 | * Small hand air bulb (no compressed air) | ||
| 37 | When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. | ||
| 38 | |||
| 39 | |||
| 40 | |||
| 41 | = Lenses/Objectives = | ||
| 42 | |||
| 43 | What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) | ||
| 44 | When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. | ||
| 45 | |||
| 46 | |||
| 47 | = Service Items (performed by Schilling/authorized personnel) = | ||
| 48 | |||
| 49 | Typical items listed in the service scope include: | ||
| 50 | |||
| 51 | * Cleaning of fans, replacement of filter mats (key for lifetime/performance) | ||
| 52 | * Cleaning of laser source and optics, laser power measurement (with protocol) |